Specification Sheet
®
Architectural & Engineering Specifications
June 2001
Ceiling or Inside Wall
Exhaust Fan
MODEL: 8310
DESCRIPTION
•
For ventilation of kitchens up to 90 sq. ft. or other rooms
up to 225 sq. ft.
• Extension-type hanger bars are included for 16" or 24"
O.C. joists or studs.
•
Housing with duct collar is 3
1
/
16
" x 11
5
/
8
" x 3
3
/
16
".
• Installs in ceiling or in 2" x 4" wall application; discharge
through 3
1
/
4
" x 10" duct.
•
Motor quietly drives electronically balanced impeller
type fan blade.
• Silver anodized aluminum grille, fastens with plated
thumbscrew that is adjustable for ceiling or wall
thickness.
• Switch operated – turn fan ON and damper opens
automatically, damper shuts tight when fan is OFF.
•
Pre-wired outlet box – plug-in receptacle.
• Refer to NuTone's catalog for a complete line of
accessories to effectively adapt this Exhaust Fan
to your construction requirements.
• Suitable for use with solid-state speed controls.
DESIGN FEATURES
Air Delivery: 180 CFM at 0.10" S.P.
Sound Level: 5.5 Sones.
Dimensions: Housing: 11
5
/
8
" x 13
1
/
16
" x 3
3
/
16
".
Grille: 11" diameter.
Material & Finish: Housing: Cold rolled steel, baked
enamel.
Grille: Aluminum, silver anodized.
Motor: Fully encased, plug-in, impedance
protected, 120vAC, 60 Hz,
1550 RPM,
1
/
54
HP, 0.78 amp,
55 watts,
5
/
16
" diameter shaft.
Fan Blade: One-piece 0.040 aluminum,
8" diameter, 6-leaf, 1
29
/
32
" pitch,
5
/
16
" hub I.D.
Duct Size: 3
1
/
4
" x 10".
INSTALLATION
• Housing is installed in ceiling or 2" x 4" wall during the
rough-in stage of construction. Adjustable hanger bars
slide through built-in tabs on housing for 16" – 24" O.C.
joists.
• The knockouts in prewired outlet box allow for connection
of house leads to be made from either above
or from the end of the unit. Motor assembly features
three (3) grommeted brackets that fasten into the ends of
three (3) mounting studs on the housing. Grille screw will
accommodate plaster or drywall thickness variances.
Installation Instructions included with each unit.
• Install at least 5 feet above floor or install above counter
or major appliance.
ARCHITECT'S SPECIFICATIONS
Exhaust Fan shall be Model 8310 as manufactured
by NuTone according to listed specifications. Fan shall
ventilate at 180 CFM at 0.10" S.P. at a sound level of
5.5 sones. Housing shall measure 11
5
/
8
" x 3
1
/
16
" x3
3
/
16
"
deep and connect to 3
1
/
4
" x 10" duct.