User's Manual
SYSTEM FAILURE MONITORING STATION DTMF CONTROL
The system will monitor itself for failures, such as: Monitoring Station can control the
dialer during a panic voice conversation.
Follow the commands below for various functions.
1) AC power failure (No AC power from the adapter)
2) Phone line failure (No phone line is connected)
3) Backup battery failure (Backup battery is low)
During a AC power failure, the dialer itself will beep every 30 seconds and the
red LED will flash. There is no beeping for phone line or backup battery failure. But
the red LED will flash. When there is failure condition, you should check the 3
mentioned failures, whether there is any loose connection between the dialer
and the AC adapter, backup battery or phone line. Once the failure is fixed, the
beeping will stop and the green LED will be on steadily.
You can also disable the beeping of AC power failure. Press the green button
while it is beeping, the buzzer will stop beeping. It will beep again if another
failure occurs. Contact ID Event Codes
You can also completely disable beeping by turning off the beep with Audible
fault alert Field Number, 63.
DTMF Digits Functions
1 One-Way Speak (Dialer)
2 Two-Way conversation
3 One-Way Listen (Dialer)
9 Disconnect
Contact ID Event Event Qualifier + Event Code
Panic – Panel Panic button 1 + 101 (zone 000)
Panic – Remote Control 1 + 101 (zone 00x) “x” is the remote
number from 1 to 4
AC loss (main unit) 1 + 301
AC back to normal after loss 3 + 301
Low battery (main unit) 1 + 302
Remote low battery 1 + 384 (zone 00x) “x” is the remote
Self Test
number from 1 to 4
1 + 602
Inactivity Report 1 + 654