User's Manual
Audible Fault Alert - Field Number 63
If audible fault alert is enabled, the dialer will sound fault alert beeps for every
30 secs when there is fault detected.
Help Arrival Signal – Field Number 64
If help arrival signal is enabled, the dialer will display this comforting signal to
indicate that the help call has been successfully acknowledged by the
monitoring center and that any help is on the way. If the GREEN RESET
BUTTON is not pressed after 15 minutes, the dialer will send one more “Help
Call” report again to summon help and to inform the Central.
Emergency Button Enable – Field Number 65
Red help button is activated when emergency button is enabled.
Silent Mode – Field Number 66
If silent mode is enabled, the dialer will operate in silent mode where all
alerting beeps will be silenced in normal operation.
AC fault report – Field Number 67
If AC fault report is enabled, the dialer will always report AC power failure to the
Central Monitoring Station according to AC power down delay.
Follow-in Function – Field Number 68
If follow-in function is enabled, the dialer will hang up the line automatically and
start a 2-minutes waiting period to auto answer incoming phone call from the
Central Monitoring Station for instant Two-Way Communication.
Access Code – Field Number 69
The access code can be set to new one.
Auto Answer – Field Number 70
The dialer can be programmed to auto answer incoming call after a pre-set
number of rings.
Guard Time Delay – Field Number 71
The dialer can be programmed to delay alarm reporting from 00 (instant
reporting) to 99 secs delay.