User's Manual
battery message to the monitoring station. However, this message will not be
sent immediately. There is a delay so that the low voltage level has to be detected
for a fixed time period before the dialer will report to the monitoring station. This
range of this delay is from 30 seconds up to 65535 seconds (~18 hours).
Recommended setting would be between 60 seconds to 300 seconds.
Dialer Low Battery Busy Delay – Field Number 46
When the low battery failure call cannot be dial successfully to the monitoring
station, it will retry after the busy delay interval.
Sensor / Remote Low Battery Delay – Field Number 47
When the battery voltage of a sensor or remote drops to certain level, the dialer
will send a low battery message to the monitoring station. However, this message will not
be sent immediately. There is a delay before the dialer will report to
the monitoring station. This range of this delay is from 30 seconds up to 65535
seconds (~18 hours). Recommended setting would be between 60 seconds to 300 seconds
Sensor / Remote Low Battery Busy Delay – Field Number 48
When the low battery failure call cannot be dial successfully to the monitoring
station, it will retry after the busy delay interval.
Self Test Busy Delay – Field Number 49
When the self test call cannot be dial successfully to the monitoring station, it will
retry after the busy delay interval.
Dial Tone Detection – Field Number 50
If dial tone detection is enabled, the dialer will dial only if a recognized dial tone is
detected. Since there are many different dial tone in various countries, cities, it is
suggested that to disable this function.
Busy Tone Detection – Field 51
If busy tone detection is enabled, the dialer will hang up after detecting the busy
signal. If such detection is disabled, the dialer will not hang up until it reaches
time out period.
PROGRAMMING OPERATION
Ringer Enable – Field Number 62
If ringer is enabled, the dialer will sound the ringing tone for audio alert.