User's Manual

PROGRAMMING
NC / NO / Momentary – Field 30
There are 3 different relay outputs.
Normal Open – Relay is open when there is no activation. Relay contact is closed
(and latched) while panic is activated.
Normal Close – Relay is close when there is no activation. Relay contact is
opened (and remains open) while panic is activated.
Momentary Contact – Relay contact will be closed momentary when panic signal
is received.
The relay output will be activated after the monitoring station picks up the call
(operator pressing [4] to confirm picking up the call). The relay output will return to
normal state when the call is finished (operator disconnects the phone line by
pressing [0][*])
Panic Voice Phone Number Redial Count – Field Number 32, 33, 34,35
Each Panic Voice Phone Number can have its individual redial setting. If the 1st
phone number is busy after the first trial, it will redial based on the redial count. If
the call is not successful after all redial count for that phone number, it will dial the
2nd phone number.
Monitoring Station Redial Count – Field Number 36, 37
If the Monitoring Station phone number is busy after the first trial, it will redial
based on the redial count.
Sensor Inactivity Alert Setting - Field Number 38, 39, 40, 41
A sensor can be programmed to the dialer as a remote, into one of the 4 remote
locations. If a sensor for monitoring purpose, i.e. a motion sensor should be
activated under normal condition at least once a day, you may set the inactivity
alert time to 24 hours, that means if the sensor does not get triggered in 1 day, an
inactivity alert Contact ID message will be sent to the monitoring station.
AC Failure Busy Delay – Field Number 44
When the AC failure call cannot be dial successfully to the monitoring station, it
will retry after the busy delay interval.
Dialer Low Battery Delay – Field Number 45
When the back up battery voltage drops to certain level, the dialer will send a low