SELECTABLE FEATURES
The selectable features of this unit can be set manually as explained above, or online by using our web link. The Accessory VE-PROG kit will include the nec-
essary cables to connect to your computer along with the web access information and application required to take advantage of this feature.
Factory default settings are indicated by BOLD text below.
NOTE: The method of manual override can either be selected to operate from the valet switch or operate by custom code. Custom Code programming is found
in the owners guide. Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
NOTE: Manual programming Keyless Entry Models with no horn output will Flash the Parking Lights instead of chirp where chirp is indicated.
Also, No data will be indicated if a feature is not available for a particular model. The unit will enter the feature but no selection will be available.
RF Programmable Feature Bank 1 Is For Transmitter Programming See Transmitter Programming Guide.
Programmable Features Bank 2 Is Alarm Selectable Features:
Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 6 Chirps
1st DoorL/UL 500 mS 3.5 Sec. 500mS L, Dbl. U/L Dbl L, 500mS UL Dbl L, Dbl UL 500mS/350mS ul
2nd Accy Lock Auto Lock On Auto Lock Off
3rd Accy. UL Auto UL Dr. Auto UL All Auto UL Off
4th Headlights On Arm On Disarm On Both Off
5th Passive Locks Passive Active
6th Pass/Act Arm Passive Arm Active Arm
7th Siren/Horn Siren/Horn Siren Only Horn Only
8th Horn Chirp 10mS 16mS 30mS 40mS 50mS
9th O/R Method Custom Code Valet
10th 2 Step U/L On Off
11th Chp Del Tx On Off
12th Trigger Circuits All On Doors Off Hood/Trunk Off All Off
13th L/UL Poll Not Available
14th Aux Ch 5 Sel Pulse Push & Hold 10 Sec 20 Sec Latch On/Off Hold 3/S For O/P
15th Aux Ch 6 Sel Pulse Push & Hold 10 Sec 20 Sec Latch On/Off Hold 3/S For O/P
16th Aux Ch 7 Sel Pulse Push & Hold 10 Sec 20 Sec Latch On/Off Hold 3/S For O/P
17th Trigger Delay Not Available
18th Data Port Select DBI Protocol ADS Protocol
If Programming via PC while connected to + 12 VDC you must manually enter the programming mode as shown below.:
Turn the ignition on
Press and release valet switch 3 times
Turn ignition off then on, off then on, off then on, off then on to enter web/on-line feature selection Bank 5.
Siren chirps 5 times indicating access to feature program mode. Launch the application on your PC,,Connect the module via the USB to DBI
harness and follow program prompts.