User's Manual

41PROPLME Install Guide rev A.
15 - Orange Wire Output: Controls the output of the orange wire. This wire will either
supply a ( - ) output when armed OR disarmed.
( - ) Armed Output - Supplies a constant negative out while the system is
armed
( - ) Disarmed Output - Supplies a constant negative out while the system is
disarmed
16 - Arming Delay: Control the type of arming; standard, delayed or armed with vehicle
remote started.
OFF - No delay when arming, normal security functionality.
45 Seconds - Delays the arming process for 45 seconds when armed using
the ARM/DISARM INPUTS, during this time the system will be disarmed if the
ignition is turned ON. No delay is added if using an aftermarket transmitter to
arm the system
Factory R/S Option - For use with vehicles with a FACTORY INSTALLED
Remote Start. If the ignition comes on within 6 seconds of arming the system,
the system will ignore ALL security inputs until 5 seconds after ignition clears
OR any remaining inputs clear after ignition has cleared.
17 - GREEN/WHITE Output Wire: Controls the GREEN/WHITE output type.
Illuminated Entry - Supplies a constant output for 1 minute.
Factory Disarm - Single 1 second puled output upon disarming the system.
18 - Lot Alert: Available in Lot Mode only - Toggle Lot Mode notication chirps ON/OFF.
OFF - No notication chirps
ON - 5 short low volume chirps each time the ignition is turn ON.
19 - Lot Mode Passive Arming Timers; TX Disarm / Ignition: Available in Lot Mode
only - Change the passive arming timers when the system is unlocked or the ignition is
turned on.
5 / 30 Minute - 5 minute timer when doors have been unlocked / 30 minute
timer after the ignition has been turned OFF.
1 / 1 Minute - 1 minute timer when doors have been unlocked / 1 minute timer
after the ignition has been turned OFF.