User's Manual

40 2014 VOXX Electronics Corporation. All rights reserved.
8 - Arm/Disarm Chirps: Controls the normal Arm / Disarm chirps. NOTE: This feature
must be ON to use system chirps even with the silent choice feature enabled
ON - Arm / Disarm chirps function as normal.
OFF - All Arm / Disarm chirps are disabled.
ON Including ITS Mode - Arm / Disarm chirps function as normal including
when in ITS Mode.
9 - Door Lock Output Timing: Controls the timing of the RED and GREEN lock output
wires.
0.9 Second - Single 0.9 second lock pulse, single 0.9 second unlock pulse.
3 Seconds - Single 3 second lock pulse, single 3 second unlock pulse.
0.9 Second Lock, Double Pulse Unlock - Single 0.9 second lock pulse, double
0.9 second unlock pulse.
0.75 Second - Single 0.75 second lock pulse, single 0.75 second unlock pulse.
10 - Ignition Controlled Locks: Control of door locks when the ignition is cycled ON or
OFF.
All (Lock & Unlock) - Doors lock when ignition is turned on and unlock when
ignition is turned off.
Lock Only - Doors lock when ignition is turned on
Unlock Only - Doors unlock when ignition is turned off.
OFF - Door locks not activated by ignition.
11 - DK BLUE Wire Output: This feature controls the type of output for the DK BLUE
wire. Setting this feature to ITS Function will change the functionality of the entire sys-
tem, refer to ITS functionality of the install guide.
Trunk - 1 second pulsed output.
ITS Function - ITS function, warn-away and full trigger.
ITS Function, Warn Away Disabled - ITS function with full trigger only
12 - Disarm Input 2 Polarity: Select the input polarity as positive or negative.
13 - Horn Output Timing: Control the minimum horn pulse time in milliseconds, some
vehicle will require a longer pulse to activate the factory horn.
10mS 16mS 30mS 40mS 72mS
14 - Real Panic Sound: Controls the horn output when the system is triggered.
ON - Randomized horn honks when panic/security is triggered.
OFF - Standard pattern horn honks when panic/security is triggered.