User's Manual
22 2014 VOXX Electronics Corporation. All rights reserved.
5 GREEN / WHITE Illuminated Entry Output ( - ) 200mA
This wire provides a 200mA output for 30 seconds when the system is disarmed and a
continuous output when the system is triggered.
Verication:This wire will register positive voltage or ground when the vehicle’s dome
light is turned ON.
Locate the vehicle’s dome light or pin switch wire.
6 DK. BLUE Trunk Release Output ( - ) 300mA
This wire provides a 500mA negative output capable of driving relays. For Control of
optional accessories such as trunk release.
• To Activate press and hold UNLOCK for 2 seconds.
Verication:This wire will register either positive voltage or ground when the trunk
release is activated.
Locate the vehicle’s trunk release wire at the trunk release switch.
5 PIN INPUT HARNESS
1 BLUE Trunk Shunt Input ( + )
This Wire, when activated, will suspend all security zones from triggering the system until
5 second after the shunt input OR the last trigger input clears.
4 LT. GREEN Instant Trigger Input ( - )
Install the supplied Hood Pin Switch and connect to the LT GREEN wire.
Verication:Thiswirewhenconnectedwillregistergroundwhenthevehicle’shoodis
opened.
Connect the LT GREEN wire to the hood pin.
NOTE: Be sure to loom the wire, and seal the grommet.