User's Manual

Location 6, events to report to pager
Phone fault detected. This location has 16 segments.
Note:
Reporting must be enabled in the control panel for this location to function.
This location selects the partitions to include when reporting to a pager. To exclude any partition from
reporting, turn off the LED corresponding to that particular partition number. Enter the numbers of the
partitions to include for each type of report found in segments 1 through 16. Factory default is all partitions
off. for all segments.
Table 11 describes the segment options.
Location 7, special events to report to pager
Phone fault detected. This location has 8 segments.
This location selects the partitions to include when reporting special events to a pager. To exclude any
partition from reporting, turn off the LED corresponding to that particular partition number. Enter the
numbers of the partitions to include for each type of report found in segments 1 through 4. Factory default is
all partitions off for all segments. Segments 5 to 8 are reserved for future use.
Table 12 describes the segment options.
Table 11. Location 6 options
Segment Description
1 Alarms
2 Open/close
3 Bypass
4 Zone trouble
5 Power trouble (AC failure or low battery)
6 Siren and telephone fault
7 Test reports
8 Program, download, and log full
Segment Description
9 Tampers
10 Short circuit and ground fault
11 Sensor lost
12 Sensor low battery
13 Expander trouble
14 Failure to communicate
15 Zone activity monitor
16 Reserved for future use.
Table 12. Location 7 options
Segment Description
1 Alarm restores
2 Telephone fault
Segment Description
3 Start download
4 Fail to communicate, data lost