Voltage Trip - Inputs 2, 3, and 4 (and 1 if set for standard input) can be tripped by applying 12
V to the + input and 0 V to the - input. A signal must be continuously present for 500 ms.
Figure 5: Wiring example for open collector trip
Open Collector - Inputs 2, 3 and 4 (and 1 if set for standard input) can be tripped by applying
12 V to the + input and the Open Collector output of the panel to the - input. A signal must be
continuously present for 500 ms.
Outputs - Outputs 1 and 2 are dry contact relays rated for a maximum of 1 A at 24 VDC, and
are in the normally open condition. The outputs can be used to control other devices at the
installation site.
Power Supply - The customer-supplied 12 VDC, 2 A rated power supply must be connected to
the unit at the 12 V terminal block connector. Terminate the positive voltage from the power
source to the “+” connector of the unit and terminate the ground of the power source to the “-”
connector. The power supply must be capable of delivering at least 2 A.
Network Expansion Port - (Future) A serial RJ45 connector is provided for future optional
external network interface that will enable the AnyNET Module to link with and report through
a broadband connection using TCP/IP protocols.
Serial Interface - The Module’s six-pin connector provides for network retransmission of
user-defined data packets via the built-in RS-232 port.
Parts required to use the interface include:
Molex - 50-57-9406 - 2.54mm (.100") Pitch SL(tm) Crimp Housing, Single
Row, Version G, Positive Latch, 6 Circuits
Molex - 16-02-0103 - SL(tm) Crimp Terminal 70058, 22-24 AWG, Bag Selective
Gold (Au)