Manual

only contain channel counts where the routing includes at least one stereo and one
surround stream.
With the number of channels selected, select the radio buttons next to the desrired
stereo source and surround target.
4. New File. With this radio button selected, files will be upmixed to a new file.
Loudness
This tab allows you to configure all of the options related to analysis and correction of
loudness parameters.
1. Auto-correct Check this option to auto-correct the files to the specifications into the
‘Correct into folder’ which is specified on the ‘File Handling’ tab.
2. Verify Checks the corrected file for conformity. This requires another scan, creating
the possibility for an iterative process to exactly meet all requirements.
3. Display options. The left column of tick-boxes allows you to choose which items
are displayed in the analysis summary of the process queue. Note that only LRA is
available from the Dynamics Adaptation section unless you have a DynApt™ license
and DynApt™ processing is turned on.
4. Specifications. The specification options are in the second column and allow you
to choose which criteria you wish to test for. If these tick-boxes are ticked, then
incoming audio is compared against the corresponding values and will pass or fail as
appropriate.
(a) Algorithm In this area the fundamental analysis algorithm is selected, governing
all loudness calculations made by this instance of AMB. AMB is capable of
performing calculations compliant with ITU-R BS. 1770-1, ITU-R BS. 1770-2/3
1
,
EBU R128 (2010)
2
, EBU R128 (EBU mode), Dialog Gate & Leq(m). Current
loudness standards are based around these algorithms eg. ATSC A/85, ARIB
TR-B32, AGCOM 219/9/CSP etc. although many delivery specifications simply
refer to the algorithm directly.
1
Our implementation of the ITU-R BS.1770-3 algorithm is also ITU-R BS.1770-2 compliant, so you can use this
setting to cover both requirements
2
The EBU R128 (2010) algorithm is a legacy setting. This uses the G8 gating system superseded by the G10
gate in the current EBU R128 algorithm.
13 © 2016 NUGEN Audio www.nugenaudio.com