Phau Ntawv Qhia
Charge on.
Page 2 8 o f 3 7 Blink IQ 2 0 0
Level 2 AC EVSE Instruction Manual 1 0 / 9 / 2 0 1 9
GPS Information
Latitude
The latitude of the Blink Product.
Longitude
The longitude of the Blink Product.
9 .3 . OCPP Settings
Configuration Item
Description
Remote Service Settings
Remote Service Type
Specifies the protocol that the Blink Product will use to communicate with a Central System.
Service Settings
Charge Point ID
The identity of the charger as known by the Central System. This setting is typically the Charge
Point Serial N umber.
Protocol N ame
The protocol that the Blink Product will use to communicate with a Central System.
Central System URL
The URL of the Central System.
Basic Auth ID
The ID for Basic authentication regarding HTTPS (SSL/ TLS) connections.
Basic Auth Password
The password for Basic authentication regarding HTTPS (SSL/ TLS) connections.
FTP Server Username
The ID that the Blink Product will use to connect to an FTP server which contains firmware
packages and ad loops.
FTP Server Password
The password that the Blink Product will use to connect to an FTP server which contains
firmware packages and ad loops.
Message Transport Layer
Indicates whether W S (W ebSocket protocol over http) or W SS (W ebSocket protocol over https)
is used.
W ebSocket Ping Interval
The interval (in seconds) between W ebSocket pings.
Boot N otification Interval
The interval (in seconds) between bootNotification retries.
Boot N otification Retries
The maximum number of bootNotification retries. A setting of -1 indicates an infinite number
of retries.
Heartbeat Interval
The interval (in seconds) between Heartbeats.
PDU Timeout
The interval (in seconds) before a Protocol Data Unit (PDU) is timed out.
Reset Retries
The maximum number of reset retries.
Download Firmware Interval
The interval (in seconds) before a downloadFirmware action is timed out.
Download Firmware Retries
The maximum number of downloadFirmware attempts.
Upload Diagnostic Interval
The interval (in seconds) before an uploadDiagnostics action is timed out.
Upload Diagnostic Retries
The maximum number of uploadDiagnostics attempts.
Download AD Interval
The interval (in seconds) before a downloadAd action is timed out.
Download AD Retries
The maximum number of downloadAd attempts.
Meter Sampling Type
Indicates whether meter events are sent after every Meter Value Sample Interval based on the
charge session start time (Periodic), after every Meter Value Sample Interval based on the
clock (Clock). If Both is selected, meter events will be sent to the Central System in a Periodic
and Clock-aligned manner.
Meter Value Sample Interval
The interval (in seconds) between meter events.
Clock Aligned Data Interval
The interval (in seconds) between meter events which are clock-aligned.