Phau Ntawv Qhia
Charge on.
Page 1 9 o f 3 7 Blink IQ 2 0 0
Level 2 AC EVSE Instruction Manual 1 0 / 9 / 2 0 1 9
7 .2 . Cha nging the M a x imum O utput (Cha rging) Current of a Cha rging Sta tion
IM PORTAN T: The maximum o utput (charging) current o f the Blink Pro duct must o nly be adjusted by
autho rized perso nnel. The maximum o utput (charging) current must not be adjusted after the Blink
Pro duct is co mmissio ned.
If a circuit b reaker is upg raded at a later time, the Blink Pro duct must be re-co mmissio ned and the
maximum o utput (charging ) current must be adjusted at that time by autho rized perso nnel.
7 .2 .1 .
O n the Configura tion page o f the unit, select the Sta tion Settings ta b.
Figure 1 1 Station Settings
7 .2 .2 .
O n the Sta tion Settings tab, enter the Maximum Charg ing Current in the M a x
Ampera ge FW Setting field. The amperag e value should be a number that is in the
fo llo wing range: 1 2 .0 to 8 0 .0 .
Figure 1 2 Maximum Charging Current (Max Amperage FW Setting)
Circuit Breaker Size
15A
20A
30A
40A
50A
80A
90A
100A
Max Amperage FW Setting
12.0
16.0
24.0
32.0
40.0
64.0
72.0
80.0
Table 4 Maximum Charging Current (Max Amperag e FW Setting)