Manual
32
Sound Level Meter
17
Measurement Unit
Select the measurement unit as follows:
dB Sound level in dBSPL
This measurement unit is permanently selected
upon connecting a NTi Audio measurement mi-
crophone with electronic data sheet.
dBu Input level in dBu
dBV Input level in dBV
V Input level in Volt
LOW - Indication
The low indicator for an individual level < is displayed when:
The measured sound pressure level is below the selected •
linear measurement range. In this case the results shown
are most likely higher than the actual sound pressure level ->
choose the next lower measurement range.
The measured sound pressure level is just above the resid-•
ual noise of the connected NTi Audio measurement micro-
phone, which reduces the measurement accuracy -> choose
another microphone dedicated for low level measurements.