Set EQt, L%: Selection of measured levels
This page allows setting the following levels:
Moving Time-average Sound Level•
Gliding LAeq with selectable time window from five seconds
to one hour. Four individual levels can be configured.
Percentile Sound Level•
Allows the individual configuration of seven static levels
-
from 1% to 99% (optional with Extended Acoustic Pack).
The
- Broadband Source for the calculation of the level sta-
tistics can be chosen from a set of different levels with
either a frequency weighting A, C or Z. The time weight-
ings F, S and the moving time-averaged sound level for one
second are supported.