Manual

236
Appendix
L
Aeq60’
+k1 Moving Time-Average Sound Level with Correction Value k1
The actual measurement position often differs to the loudest posi-
tion of the live event. Thus the correction value k1 is the correction
value of L
Aeq60’M
between the loudest position and the actual
measurement position, measured using pink noise. The correc-
tion value k1 is measured or manually set in the page K
SET of the
sound level meter function.
Application: Measurements in accordance with SLV
->
->
->
L
AF
Actual Sound Pressure Level
SPL with A frequency weighting and F time weighting, compen-
sating for human hearing perception at lower sound pressure lev-
els; applicable at levels lower than 100 dB.
->
->
->
L
AFmax
Maximum Sound Pressure Level
Measures the maximum environmental noise level during the
measurement period.
->
->
L
AFmax
dt Maximum Sound Pressure Level “delta t” in report
Maximum level of the preset logging interval in the LOG-menu,
e.g. 1 second.
L
AFmin
Minimum Sound Pressure Level
Measures the minimum environmental noise level during the
measurement period.
->
->