User manual

61
Sound Level Meter
Manual Setting of Correction Values
You may fine-tune the correction values k1 and k2 manually.
Such fine-tuning adds the remark “Manually Adjusted” in the
log file.
2
3
1
Turn the rotary wheel • to select the correction value
3
and press enter
.
The selected correction value starts flashing.
Set the correction value with the rotary wheel • .
The note “Manually Adjusted” is displayed at
2
.
To undo the manual setting turn the rotary wheel •
to select
the parameter UNDO at
2
.
Confirm with enter •
.
Reset Correction Values
You may clear all correction values back to zero
by pressing the Clear All
1
and confirm with
enter
.
Display k1 and k2 during Measurement
The correction values k1 and k2 can be dis-
played in the numeric result page during the on-
going sound level measurement instead of any
other sound levels.
Correction Values in Profiles
The correction values k1 and k2 can optionally
be stored within profiles. Loading the profile,
sets the stored correction values.