User manual
59
Sound Level Meter
Level Difference
Prior to the start of the live event, the level difference between
the loudest and the measurement position is measured. The
XL2 Analyzer calculates the level difference automatically based
on the individual sound level measurements at both locations.
This level difference is included in the sound level reading dur-
ing the live event, and the XL2 thereby displays and records the
sound pressure level of the loudest point.
XL2 positioned at FOH
Loudest
Audience
Position
Level difference
Measurement
Position
(Microphone)
audience area
How to Measure the Correction Value
Play a pink noise signal at the typical sound pressure level of •
the live event. (signal source Minirator, NTi Audio Test CD)
Select the correction page •
.
Search the audience area for the location with the highest •
sound pressure level and position the XL2 Analyzer.
Turn the rotary wheel •
to select the parameter RUN next
to Audience and press enter
.
The XL2 measures the sound level at the loudest position
for 5 seconds. The timer counts down to zero.