User manual

58
Sound Level Meter
Correction Value KSET
The correction value page offers a measurement wizard for live
event monitoring, applicable in case the measurement location
differs from the loudest position in the live event area.
Measurement Position
The goal at live event monitoring is to measure the sound level
at the loudest position accessible by the audience. Setting up
any sound level measurement at this loudest location is typi-
cally not practical, thus an alternative measurement position is
chosen. The recommended measurement position in order to
minimize the influence that audience noise has on the mea-
surement:
Mount the measurement microphone in front of the main •
speakers
Position the XL2 Analyzer at front of house (FOH)•
Connect the XL2 Analyzer and measurement microphone •
using a professional audio cable
Positioning the measurement microphone at
front of house (FOH) may result in audience
noise interfering with the measurement results.
The audience noise will be further amplified by
the measured k-values.
2
1
1
Correction k1
The correction k1 is based on the LAeq.
2
Correction k2
Select the level type for correction k2.
LCpeak
for Germany DIN15905-5;
correction is based on LCpeak measurement
LCeq correction is based on LCeq measurement