User manual
55
Sound Level Meter
How to Setup the XL2 for Triggered Event Measurements
Select the logging page, set• Logging On, Interval dt:
00:00:01 and choose the required log values.
Setup the event page. For example, the screenshot below •
starts the event recording after L
AF
exceeds 80 dB for 2 sec-
onds and stops after L
AF
is lower than 70 dB for 3 seconds.
Select the memory menu and create a new folder. This folder •
will then be displayed in the memory menu. All log data and
event wav-files are stored in this folder.
The XL2 is ready for the triggered event measurement.
Logging Enabled
Triggered-event recording requires the activa-
tion of sound level logging. Using the default
Interval dt: 1 second is recommended.
Auto Save
If Log Audio
5
is set to Events Only, then
the XL2 sets per default Naming+Saving: auto
in the memory menu. This ensures that the re-
corded triggered event data is stored on the SD
Card.
For convenience, in case more than 20 triggered
events have been recorded, the Autosave ->
Delete function is disabled, as deleting such
multiple wav-files on the XL2 is time-consum-
ing.
Wav-files
All triggered-event wav-files are stored in an in-
dividual folder. For details see chapter Logging.