User manual

53
Sound Level Meter
11
Trigger and Marker Monitor
Answers the question: What caused the triggered event?
Lvl Event automatically triggered by level.
1 Event triggered or marker added by pressing key 1
of the XL2 Input Keypad.
2 Event triggered or marker added by pressing key 2
of the XL2 Input Keypad.
3 Event triggered or marker added by pressing key 3
of the XL2 Input Keypad.
4 Event triggered or marker added by pressing key 4
of the XL2 Input Keypad.
12
Stop Duration
See
3
.
13
Start Duration
See
2
.
14
Hysteresis
See
3
.
Trigger Events: on external key press
Trigger Events by pressing a button on the external input key-
pad with automated or manual stop of the event.
100
90
80
70
60
Time [seconds]
Event Duration
15
Event Duration
15
key press
Level [dB]
key press
Features:
The levels L•
Aeq
, L
Zeq
and L
CPeak
are recorded for the event
duration.
Audio data may be recorded for the user-defined event dura-•
tion
15
after the key press.
Retrigger with every repeated key press within the event •
duration.