User manual
46
Sound Level Meter
6
Log Value Setting
Choose between the following settings:
ALL Logs all available sound pressure levels with-
out correction values.
Selected Logs a subset of up to 10 different sound
pressure levels, including correction values if
you require.
Select • Log Values with the rotary wheel
.
Press enter •
to toggle between All and Selected.
7
Selected Log Values
By setting Selected at
5
up to 10 individual log values can
be chosen.
Select the first value • Lxx with the rotary wheel
and
press enter
.
The pop-up window for level selection appears.
Select the logging level with the rotary wheel •
and con-
firm with enter
.
At 100ms Logging is the log value selection limited to five
different parameters.
Wav-File Recording
The XL2 records a wav-file of the measured input signal and
stores it on the SD Card. The available formats are:
Compressed• (default, using ADPCM compression). A new
wav-file is started automatically after 12 hours of recording
(typical maximum wav-file size = 512 MByte)
Compressed+AGC• , compressed with automated gain con-
trol. The gain control increases the level of low-level signals,
so that the wav-file is well-leveled during playback on the
PC.
24Bit_48kHz• , linear wav-file logging in 24 bit, 48kHz resolu-
tion with the optional Extended Acoustic Pack. A new wav-
file is started automatically after 1 hour of recording (typical
maximum wav-file size = 512 MByte)
Broadcast Wave Format BWF
The XL2 stores scaling factor, serial number,
date, time and time zone within the wav-file (ac-
cording to EBU TECH 3285). This information is
available through professional audio/video tools
typically used in broadcast.