User manual

179
Capture + Tolerances
#ZTolerances Defines the tolerance band for the
Z-weighted wideband level (not mandatory).
#BandSum
Tolerances
Defines the tolerance band for the
sum of displayed frequency bands (not man-
datory).
#Band
Tolerances
Defines the tolerance band for the individual •
frequencies.
The ideal parameter can be set as “undef. •
The same frequency value on two succes-•
sive rows defines a tolerance step, e.g.:
Frequency Min Ideal Max
100 70 75 80
500 70 75 80
500 75 80 90
1000 75 80 90
#LevelOffset All levels in the tolerance file are relative levels
dBr. Thus the level offset provides the relation
between the relative level and actual sound
pressure level. (not mandatory)
The XL2 allows setting of the level offset inde-
pendently of the tolerance file.
#Hide
UnusedBands
Defines the way measurement results are
shown.
True Measurement
results
of fre-
quency bands without any
specified tolerance are not
displayed. The total level of all
shown bands (sum of bands) is
available as a broadband result.
False The measurement result of all
frequency bands are shown.
#nAllowed
Violations
Allows a PASSED result with a maximum
number of n failed frequency bands (not man-
datory)