User manual

178
Capture + Tolerances
#Unit
dBr
#Mode
HighLow
#Columns
Frequency Min Ideal Max
#ATolerances
UNDEF 80 unde
f
90
#ZTolerances
UNDEF 80 unde
f
90
#BandTolerances
20 70 unde
f
80
1000 70 unde
f
80
1000 73 unde
f
77
4000 73 unde
f
77
4000 70 unde
f
80
20000 70 unde
f
80
#LevelOffset
0
#HideUnusedBands
false
#nAllowedViolations
0
#Unit dBr (relative), fixed setting
#Mode Describes tolerance type; the XL2 allows set-
ting of the tolerance type independently of the
tolerance file.
HighLow Utilizes
upper and lower toler-
ance based on ideal reference.
High Utilizes only upper tolerance
based on ideal reference.
Low Utilizes only lower tolerance
based on ideal reference.
#Columns Column headings for further tolerance data
separated into columns:
Frequency / Min / Ideal / Max
#ATolerances Defines the tolerance band for the
A-weighted wideband level (not mandatory).
#CTolerances Defines the tolerance band for the
C-weighted wideband level (not mandatory).