User manual

140
Vibration Meter
123 Values: Vibration Meter
Displays the selected broadband vibration level results. You can
change the font size of the result. Depending on the font size
chosen, the XL2 shows 2 up to 4 results simultaneously. The
display of the actual or maximum level can be selected with
the applicable frequency weighting. The peak levels PK or P-P
are real peak levels.
Spectrum: Constant Percentage Bandwidth CPB
Displays the 1/3 or 1/1 octave spectrum of the selected RMS
vibration level. Additionally the wide band result B is shown
graphically by a bar.
Reporting: Report Setting
Here you set which vibration levels shall be stored in a .txt file
after the completed measurement. Choose between:
ALL Stores all vibration levels.
Selected Stores up to 10 different individually-defined vi-
bration levels.
For details refer to the chapter Reporting.
Logging: Setup of Data Logging
The XL2 features a powerful vibration level meter data logger,
which allows you to record all required vibration level values
during the measurement. In the logging page you set which
vibration levels shall be logged over time. For details refer to
the chapter Logging. Choose between:
ALL Logs all vibration levels.
Selected Logs up to 10 different individually-defined vibra-
tion levels.
Limit LED: Limit Setting
H
ere you set the function
of the limit LED , thereby highlight-
ing any vibration level that exceeds the pre-set limits in orange
or red color. Further, external peripherals are controlled by the
optional Serial I/O Interface based on the vibration level, such
as displaying vibration levels on a large external red-orange-
green lamp. For details refer to the chapter Limits.