User manual
134
STIPA
Hints: Measurement
Select measurement positions as stipulated by local regula-•
tions. As a guideline, typically position the microphone at 1
- 1.2 meters above ground in sitting areas or 1.5 - 1.8 meters
in standing areas. Also, directly in front of the speakers or
very close to a wall are examples of positions that are not
typical.
The person taking the measurements should be out of the •
acoustic field, so as not to affect the measurement results.
For this purpose the measurement microphone can be
mounted on a microphone stand and connected with the
ASD Cable to the XL2.
Low speech intelligibility readings can be caused by•
Excessive sound reverberation, echoes or reflections
-
Poor speaker directivity or speaker coverage
-
Speaker level setting incorrect; e.g. low signal-to-noise ra-
-
tio.