Operation Manual

SKYWATCH AWS
Air Warning System
Presentation :
The system features a display box, a cabled sensor and a wind turbine.
The cabled sensor includes the humidity and temperature sensors as well as the
wind coil. The wind sensor itself is a wind turbine that is screwed near the coil.
The display box features an LCD with 3 levels (wind / humidity / temperature).
The user can set up all alarm levels easily with the push buttons.
Once an alarm is reached, the corresponding led and buzzer will warn for 15
seconds.
The alarm keeps beeping and flashing every 15 seconds until the user receipted the
alarm. As long as an alarm is active, the corresponding led keeps flashing (values
that have alarmed will stay displayed).
Features :
Windspeed :
Units : km/h, mph, knots, m/s and fps
Resolution : 1 km/h
Accuracy : 3 %
Update : 1 measure per second with an average on 2 seconds.
Minimum speed : 1 to 3 km/h
Maximum speed : more than 250 km/h
Alarms : 2 levels, Hi et Lo programmable by pitch of 1 unit
Humidity :
Unit : %rH
Resolution : 0.5 %rH
Accuracy : +/- 3%rH (20 - 80%rH)
Update : 1 measure every 16 seconds
Minimum value : 2 %rH
Maximum value : 100 %rH
Alarms : 2 levels, Min et Max programmable by pitch of 1 %rH
Temperature :
Units : °C, °F
Resolution : 0.5 °C
Accuracy : ± 0.5 °C
Update : 1 measure every 16 seconds
Minimum value : -20°C
Maximum value : 80°C
Alarms : 2 levels, Min et Max programmable by pitch of 1°