Datasheet

Electrical Characteristics: (Note 2, Note 3)
Parameter Symbol Test Conditions Min Typ Max Unit
Input Clamp Voltage V
IK
V
CC
= MIN, I
I
= 18mA 1.5 V
High Level Output Voltage V
OH
V
CC
= MIN, V
IH
= 2V, V
IL
= MAX, I
OH
= -0.4mA 2.7 3.4 V
Low Level Output Voltage V
OL
V
CC
= MIN, V
IH
= 2V,
V
IL
= MAX
I
OL
= 4mA 0.25 0.4 V
I
OL
= 8mA 0.35 0.5 V
Input Current
J or K
I
I
V
CC
= MAX, V
I
= 7V
0.1 mA
CLR or PRE 0.3 mA
CLK 0.4 mA
High Level Input Current
J or K
I
IH
V
CC
= MAX, V
I
= 2.7V
20 A
CLR or PRE 60 A
CLK 80 A
Low Level Input Current
J or K
I
IL
V
CC
= MAX, V
I
= 0.4V
0.4 mA
All Other 0.8 mA
ShortCircuit Output Current I
OS
V
CC
= MAX, Note 4, Note 5 20 100 mA
Supply Current I
CC
V
CC
= MAX, Note 6 4 6 mA
Note 2. .For conditions shown as MIN or MAX, use the appropriate value specified under “Recommended
Operation Conditions”.
Note 3. All typical values are at V
CC
= 5V, T
A
= +25C.
Note 4. Not more than one output should be shorted at a time, and duration of the shortcircuit
should not exceed one second.
Note 5. For certain devices where state commutation can be caused by shorting an output to ground,
an equivalent test may be performed with V
O
= 2.125Vand the minimum an maximum limits
reduced to one half of their stated values.
Note 6. With all outputs open, I
CC
is measured with the Q and Q outputs high in turn. At the time of
measurement, the clock input is grounded.
Switching Characteristics
: (V
CC
= 5V, T
A
= +25C unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Maximum Clock Frequency f
max
R
L
= 2k, C
L
= 15pF 20 45 MHz
Propagation Delay Time
(From PRE
, CLR or CLK input to Any Q Output)
t
PLH
15 20 ns
t
PHL
15 20 ns
Function Tables:
Inputs Outputs
PRE CLR CLK J K Q Q
L H X X X H L
H LXXXLH
L LXXXH { H {
H H LLQ
0
Q
0
H H HLHL
H H LHLH
H H H H Toggle
H H H X X Q
0
Q
0
{ This configuration is nonstable; that is, it will not persist
when wither preset or clear returns to its inactive (high) level.