Datasheet
Electrical Characteristics: (T
A
= 0° to +70°C, Note 2 unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Input Clamp Diode Voltage V
IK
V
CC
= Min, I
I1
= −12mA − − −1.5 V
Output High Voltage V
OH
V
CC
= Min, V
IH
= 2V, V
IL
= 800mV,
I
OH
= −0.4mA
2.4 3.4 − V
Output Low Voltage V
OL
V
CC
= Min, V
IH
= 2V, V
IL
= 800mV,
I
OL
= 16mA
− 0.2 0.4 V
Input Current I
I
V
CC
= Max, V
I
= 5.5V − − 1 mA
Input High Current
D
I
IH
V
CC
= Max, V
I
= 2.4V
− − 40 mA
CLR − − 120 mA
All Others − − 80 mA
Input Low Current
D
I
IL
V
CC
= Max, V
I
= 0.4V
− − −1.6 mA
PRE (Note 3) − − −1.6 mA
CLR (Note 3) − − −3.2 mA
CLK − − −3.2 mA
Output Short Circuit Current I
OS
V
CC
= Max, Note 4 −18 − −57 mA
Power Supply Current I
CC
V
CC
= Max, Note 5 − 8.5 15 mA
Note 2. All typical values are at V
CC
= 5V, T
A
= +25°C. For conditions shown as Min and Max, use
the appropriate value specified under recommended operating conditions.
Note 3. Clear is tested with preset high and preset is tested with clear high.
Note 4. Not more than one output should be shorted at a time.
Note 5. With all outputs open, I
CC
is measured with the Q and Q outputs high in turn. At the time of
measurement, the clock input is grounded.
Switching Characteristics: (V
CC
= 5V, T
A
= +25°C unless otherwise specified)
Parameter Symbol
From
(Input)
To
(Output)
Test
Conditions
Min Typ Max Unit
Maximum Clock Frequency f
max
R
L
= 400Ω,
C
L
= 15pF
15 25 − MHz
Propagation Delay Time
Low−to−High
t
PLH
PRE or
CLR
Q or Q − − 25 ns
High−to−Low t
PHL
− − 40 ns
Propagation Delay Time
Low−to−High
t
PLH
CLK Q or Q − 14 25 ns
High−to−Low t
PHL
− 20 40 ns