INSTRUCTION MANUAL LISTED DIGITAL TIME SWITCH 7 DAY DG100A DGM100A DG200A FOR TECHNICAL SUPPORT: 888.500.4598 A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.
TABLE OF CONTENTS Section Page Installation Instructions and Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.0 Clock Format . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.0 Clock Set Mode . . . . . . . . . . . . . . . . . . . . . . . . 2 3.0 Date Set Mode . . . . . . . . . . . . . . . . . . . . . . . . 2 4.0 Daylight Saving Time . . . . . . . . . . . . . . . . . . . . 3 4.
TORK MODEL DG100A/DGM100A/DG200A 7 DAY DIGITAL TIME SWITCH READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL TIME SWITCH. SEE WARNING ON FRONT PANEL – Failure to comply with instructions could result in personal injury and/or property damage. INSTALLATION: UNIT IS TO BE INSTALLED BY A LICENSED ELECTRICIAN 1. Remove unit from enclosure by pushing the inside tab (located near the outside hasp) to the right. Swing unit to left and remove. 2.
FEATURES Daylight saving - Automatic (user selectable) Leap year - Automatic compensation Power outage - Permanent schedule retention. Super capacitor provides 7 days of real time back up. Manual override - Until the next scheduled event AM/PM or 24 hour format - user selectable Multi-Voltage Input: 120 – 277VAC 1.0 CLOCK FORMAT The first time unit is powered up, it will display a flashing 12 Hour. Use HOUR key to set clock format to either 12 Hour (AM/PM) or 24 Hour. Press the ENTER key. 2.
Press MONTH, DATE, and YEAR key to advance to the desired month, date and year, then press ENTER. NOTE: The day of the week will automatically set once the date is entered. 4.0 DAYLIGHT SAVING TIME After setting or modifying the date, display will show: a. For standard USA daylight savings (DSt), press MODE and go to step 5.0. b. For dates other than standard USA dates, press MONTH and go to step 4.1. c.
is Sunday (SU.) Once modified date set, the unit will automatically calculate the correct start dates in the future. Now press MONTH and DATE buttons to modify the starting DST settings. Pressing DAY changes default day. EXAMPLE: A screen showing “04:01 SU S” repre sents April (04), the first week (01), Sunday (SU), and the Start (S) of daylight savings time. Press ENTER to save and the display will show: Now press MONTH and DATE buttons to modify the ending DST settings. Pressing DAY changes default day.
You are able to select up to 9 holiday blocks, which will exclude all of the regular schedules, and execute a special set that will only run on those specified days. If no holiday schedule is entered in step 6, operations will be omitted during the block. Holiday blocks can be anywhere from 1 day in length (the same start and end dates) or up to 364 days. Holiday blocks cannot end after they begin.
Press the ENTER key. Repeat for all holidays. Press MODE when holidays are complete. 6.0 SCHEDULE SET MODE 6.1 SETTING HOURS, MINUTES, AND DAYS Note: A schedule is needed for each event. If a typical ON/OFF pair is required, use SCH 01 for the ON event and SCH 02 for the OFF event. Press the HOUR, and MIN keys to set the desired time. Press EVENT to set desired event (ON or OFF) Press CH SELECT key to select channel on DG200A. Press DAY to set desired day(s).
Note: Selection #12 will only show if a holiday date has been entered in step 5. Press ENTER to save. Follow the same procedures above to set more schedule entries. Press MODE when schedules are complete. Unit is in the AUTO (automatic) mode. The word FLASH may appear to indicate a new program has been written to memory.
Press the EVENT key once (or twice for two circuit units) to activate current schedule then EVENT key again to return to AUTO mode. 7.0 REVIEW, MODIFY AND DELETE Press MODE to advance to any of the following MODES: 1. AUTO MODE: In this automatic mode, the unit will execute the scheduled programs. Time, day, seconds and load status are displayed. If today is a programmed holiday, the day of the week will flash.
4. DATE MODE: Press MONTH, DATE and YEAR to modify existing settings. Press ENTER to save changes. DAY is automatically adjusted. 5. DSt MODE: Factory default is set at US standard daylight savings dates noted by ON. To remove daylight savings time setting, press DEL to change screen to show OFF. DST may be activated again by pressing DEL. Press ENTER to save changes. To change from the standard DST month/ week/day setting press HOUR and refer to step 4.1. 6.
Use the EVENT key to display: Now Press ENTER briefly and everything in the timer memory is cleared and 12HOUR will flash. 4. A “PF” on the display indicates a Power Failure and the unit requires AC power to operate. The time and date are protected for 7 days by the super cap. The program is retained in permanent memory. 5. A “Lo” on the display indicates that the super cap has run low and the unit needs to be powered with AC. A minimum of 8 hours is required to fully charge the super cap.
DG100A DG100A DG100A 120/277VAC 120/277VAC 120/277VAC DGM100A DGM100A DGM100A 120/277VAC 120/277VAC 120/277VAC DG200A DG200A DG200A 120/277VAC 120/277VAC 120/277VAC 11
12
13
A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.