Instruction Manual
17
Figure 5-12 0-9
5.3.11 High Temperature Alarm
Click the switch icon of [High temperature Alarm], and a window for setting the
high temperature alarm threshold value pops up on the interface, as shown in the
figure below When the maximum temperature value in the screen is higher than the
alarm threshold value (in the regional temperature measurement mode, the
temperature in the region is taken as the benchmark, except point measurement),
the system will sound an alarm, and the video screen will flash a red alarm.
Figure 5-13 0-10