Technical Data Versions for Mobile Applications
These versions are optimzed for the high requirements in mobile applications.
Tested to the highest requirements as ISO-pulse and high interferences to ISO 11452.
Type designations RFC - 4801 - _ _ _ - 2 _ _ - _ _ _ RFC - 4801 - _ _ _ - 3 _ _ - _ _ _ RFC - 4801- _ _ _ - 3 2 _ - _ _ _
ratiometric voltage current
Mechanical Data
Dimensions see dimension drawing
Mounting with 2 M4 screws (included)
Mechanical travel 360 continuous °
Maximum operational speed unlimited
Weight ca. 50 g
Electrical Data
Supply voltage Ub 1 or 2 x 5 (4,5 ... 5,5) 12/24 (9...34) 12/24 (9 ... 34) VDC
Current consumption (w/o load) typical 15 (typ. 8 on request) per channel mA
Reverse voltage protection yes, only supply lines yes yes
Short circuit protection (vs. GND and +Ub) yes
Measuring range 0 ... 30 up to 0 ... 360, in 10° steps °
Number of channels 1 / 2 1 / 2 1
Update rate 5000 typ. measur./s
Resolution 12 bit
Repeatability 0.1 °
Hysteresis < 0.1 °
Independent linearity ≤ 0.5 of signal range %
Output signal ratiometric to Ub 0.25...4.75 V 4...20 mA
0.25...4.75 V 0.5...4.5 V (burden max. 250 Ω)
0.5...4.5 V (load >
10 kΩ)
(load >1 kΩ)
TC at measuring range 30 up to 170° typ. 100 typ. 150 typ. 150 ppm/K
TC at measuring range 180 up to 360° typ. 50 typ. 80 typ. 80 ppm/K
Insulation resistance (500 VDC) ≥ 10 MΩ
Cross-section cable approx. 0.14 mm
2
Cross-section lead wires 0.5 mm
2
Environmental Data
Temperature range -40...+125 -40...+125 -40...+105 °C
-40...+125, if Ub ≤ 28V °C
generally -20...+85 with M12 connector °C
Vibration (IEC 60068-2-6) 5...2000 Hz
A
max
= 0.75 mm
a
max
= 20 g
Shock (IEC 60068-2-27) 50 (6 ms) g
Life mechanical unlimited
MTTF 290 (single) 91 (single) 109 years
209 (partially redundant) 86 (partially redundant) years
164 (fully redundant) years
Protection class (DIN EN 60529) IP67 / IP69k (not with M12 connector)
EMC compatibility ISO 11452-2 Radiated EM HF-fields, Absorber- ISO 11452-5 Radiated EM HF-fields, Stripline: 300V/m
hall: 100V/m ISO 11452-2 Radiated EM HF-fields, Absorber hall: 100V/m
ISO 11452-4 BCI (Bulk current injection): 100mA ISO 7637-2 pulse 1a, 2a, 3a, 3b, 4, 5
CISPR25 Radiated emission: GW5 ISO 7637-1/2/3
SAE J1113-2 Conducted immunity: level 2 ISP TR10605 Packaging and handling + Component test: 8kV/15kV
SAE J1113-13 Packaging and handling: 4-20kV CISPR25 Radiated emission: GW5
SAE J1113-22 Radiated magnetic field: 80uT ISO 7637-3 Transient transmission (on/off): SG3
SAE J1113-26 AC power line electric field: 15kV
EN61000-4-2 Immunity to static discharges
(ESD): 4kV, 8kV, 15 kV
EN 55011/EN 55022/A1 radiated disturbances: class B
Versions for Mobile