User Manual
70
settings Low Value 0, High Value 16 and Step Value 5 then on alternate button presses the value sent would be 0, 5, 10,
15, 16, 0, 5…. If you want a button to step down instead of up then make the Low Value larger than the High Value. The
Step Value range is 1-64.
The ‘MOMENTRY’ option is not available for the drum pads because they only respond to a hit and do not have a
mechanism to detect when you release your finger from them. Instead of ‘MOMENTRY’ they have a special ‘VELOCITY’
option. When this is set, the value sent out when you hit the pad will depend on how hard you hit it. The control value is still
constrained within the Low Value and High Value settings. As an example if Low Value is 0 and High Value is 127 then a
soft hit will give a value near 0, a medium hit will give a value near 64 and a hard hit will give a value near 127. If Low Value
is 2 and High Value is 0 then a soft hit will give value 2, a medium hit will give value 1 and a hard hit will give 0.
Name: This setting can be found on the second page of control settings so scroll up to access it. Here you can set the
name for the control that appears on the ReMOTE ZeRO SL displays. The control name can be a maximum of 8 characters
long. To enter a character first use the encoders or buttons in line with the ‘<’ and ‘>’ symbols on the display to move the
cursor to where you want to enter the character. Then use the buttons in line with ‘Upper’, Lower’ and ‘Punctu’/’Number’
to select the type of character you want to enter (upper case, lower case, punctuation or number). Note that repeated
presses of the button below ‘Punctu’/’Number’ will switch between ‘Punctu’ and ‘Number’. Finally use the encoder, pot or
buttons in line with ‘CHAR’ to select the character you want to enter. If you want to enter a space then select ‘Punctu’, as
the first punctuation character is a blank space.
1
4.2 NON-ReGISTeReD PARAMeTeR NUMBeR (NRPN)
The DispType, LowVal, HighVal, Ports, MidiChan, Response, BtnType and Name settings are the same as for Control
Change (CC) so see the previous section for information on these settings.
NRPN lsb (Non-Registered Parameter Number Least Significant Byte): This allows you to set the NRPN lsb value for
the control to a value from 0 through 127.
NRPN msb (Non-Registered Parameter Number Most Significant Byte): This allows you to set the NRPN msb value
for the control to a value from 0 through 127.
You can toggle the display format of the NRPN lsb and NRPN msb settings between decimal and hexadecimal by pressing
the ROW-SELECT button for the upper left-hand row of buttons.