Adam Equipment WBZ and WBZ..aM SERIES (with EC or NTEP type Approval) (P.N. 9042, Rev. H, December 2010) Software rev.: 2.
© Adam Equipment Company 2010
CONTENTS 1.0 INTRODUCTION ...................................................................................................... 3 2.0 SPECIFICATIONS.................................................................................................... 3 3.0 INSTALLATION ........................................................................................................ 4 3.1 3.2 3.3 LOCATING............................................................................................................
© Adam Equipment Company 2010 2
1.0 INTRODUCTION The WBZ series of digital price-computing scales are EC Type approved, (type approval number T7476/TC7477) and the WBZ..aM series are NTEP approved scales, (type approval number 10-082). These scales provide an accurate, fast and versatile method of computing price by weight.
3.0 INSTALLATION 3.1 3.2 LOCATING • The scales should not be placed in a location that will reduce the accuracy. • Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. • Avoid unsuitable tables. The table or floor must be rigid and not vibrate. • Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors. • Do not place near vibrating machinery.
3.3 SETTING UP • The scale comes with a stainless steel platform, packed separately. • Place the platform on the top. Do not press with excessive force as that could damage the load cell inside. • Level the scale by adjusting the four feet. A spirit level is located at the rear panel. • The scale should be adjusted such that the bubble in the spirit level is in the centre of the level and the scale is supported by all four feet.
4.0 KEYPAD [0[ to [9] Numeric entry keys to set the unit price. Some keys will have secondary functions if set at the factory which are as follows: [0] / kg/100g [1] / bL [2] / SLEEp [4] / €,£,$,R,¥,None [>Z<] [Tare] [0/I] Select price per kg or per 100g Black-light Control Control of Auto Off function Selection of monetary Symbol NOTE: All secondary functions may not be enabled for all scales. This will depend on the location where the scale is used and the settings performed at the factory.
6.0 SYMBOLS AND INDICATORS Symbols 0 Net Description Scale is in the zero position Net weight is being displayed Weighing result is stable kg /kg, /100 g Active weighing unit Price per kilogram or per 100g Indicates full battery strength. Will show less number of bars for weaker strength. €,£,$,R,¥, None Active Currency 7.0 BATTERY OPERATION • The scale has an internal rechargeable lead acid battery. This enables the scale operate for 50 hours when fully charged or less if the backlight is on.
• The battery should be charged for 12 hours for full capacity. • Above the display is a LED to indicate the status of battery charging. When the scale is plugged into the mains power the internal battery will be charged. If the LED is green the battery is being charged. If it is red it is nearly discharged and yellow indicates the battery is increasing the charge level. Continue to charge overnight for a complete re-charge. 8.
10.2 TARING • Taring is used to eliminate the weight of a container so that only the net weight is displayed. On the WBZ 15 scales the tare is limited to 9.995kg. Weight above this amount will not be tared. • Zero the scale by pressing [ Z ] if necessary. The zero indicator will be on. • Place an empty container on the platform. The weight of the container will be displayed. • Press [Tare] to zero the scale.
10.3 WEIGHING To determine the weight of a sample, first tare an empty container if used, then place the sample in the container. The Weight window will show the weight and the unit of weight currently in use. To hide the currency symbol, set the currency to “None”. See section 13.5. 10.4 DETERMINING VALUE OF A PRODUCT BY WEIGHT • To determine the cost of a product by weight, it is necessary to enter the unit price per kilogram or per 100g using the numeric keys.
11.0 RS-232 Not available for WBZ Scales. 12.0 CALIBRATION 12.1 CALIBRATION PROCEDURE The scales have methods to either prevent or control unauthorised calibration. If the Calibration Counters are enabled the scales can be calibrated without breaking the seals, however the counters will be incremented to identify a calibration or change in parameters. If the scales do not have the counters enabled then access is controlled by breaking the seals on the scale to gain access to the circuit boards inside.
An alternative method would be to use tamper-evident labels over the screw on the bottom cover and over the joint between the top and the bottom cover as shown in the adjacent figure. Metrology labels and additional security measures may be added to the scale as required by the national legislation. NOTE: IF THIS SEAL IS BROKEN THE SCALE MUST BE RE-SEALED BY THE RELEVANT AUTHORITIES USING EITHER THE LEAD WIRE SEAL OR AN ACCEPTABLE SEAL BETWEEN THE COVER AND THE BASE. WBZ..
• Press the [0] key to scroll through the available options. • When the desired setting is displayed, press the [Tare] key to save the setting. The scale will return to weighing. • Press the [ Z ] key to exit a parameter. 13.1 PRICE /kg AND /100g NOTE: Not applicable for South Africa and Far East as this feature is disabled at the factory. The scale can be set to display the total cost using the unit price per kilogram or the price per 100g.
13.3 AUTO POWER OFF This parameter may be enabled or disabled by the user. If enabled, when the scale is not used for some time (as pre-set by the user under this function) it will switch off automatically. To set this parameter• Press and hold the [2] key for about 4 seconds during the normal operation.
13.5 CURRENCY SYMBOL User can select the currency symbol from the options- €, £, $, R, ¥, None (no symbol). To set the currency• Press and hold the [4] key for about 4 seconds during the normal operation • Press the [0] key to scroll through the following options • Press the [Tare] key to save the desired setting. The scale will return to weighing. The selected symbol is displayed in the Unit Price and Total Price window.
14.0 ERROR CODES During the initial power-on testing or during operation, the scale may show an error message. If an error message is shown, repeat the step that caused the message. If the error is still shown contact your supplier for support. ERROR Err 4 DESCRIPTION POSSIBLE CAUSES Initial Zero is greater than allowed when power is turned on or the Zero key is pressed. Err 6 A/D count is not correct when turning the scale on. Weight is on the pan when turning the scale on.
16.0 SERVICE INFORMATION This manual covers the details of operation. If you have a problem with the scale that is not directly addressed by this manual then contact your supplier for assistance. In order to provide further assistance, the supplier will need the following information which should be kept ready: A. Details of your company -Name of your company: -Contact person’s name: -Contact telephone, e-mail, fax or any other methods: B.
17.0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components failed due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company. The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops depending on the severity of the problems.
EL oFF EL on EL AU Press the [Tare] key Unit kg Unit 100g Press the [Tare] key 19 SLP 0 SLP 1 SLP 5 SLP 10 Press the [0] key to change Press the [0] key to change © Adam Equipment Company 2010 Press the [0] key to change Press the [1] key for 4 seconds while in normal weighing mode Press the [0] key for 4 seconds while in normal weighing mode Press the [Tare] key Press the [2] key for 4 seconds while in normal weighing mode Backlight Price /kg or /100g Auto Power Off Parameter Layout for WB
Adam Equipment ADAM EQUIPMENT, BOND AVENUE, DENBIGH EAST INDUSTRIAL ESTATE, MILTON KEYNES, MK1 1SW, U.K. Tel: (01908) 274545 Fax: (01908) 641339 Intl Tel: -44 1908 -274545 Intl Fax: -44 1908 641339 E-Mail Address: info@Adamequipment.co.
FCC COMPLIANCE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 35 years experience in the production and sale of electronic weighing equipment. Adam products are predominantly designed for the Laboratory, Educational, Medical, retail and Industrial Segments.