Manual
12.2 ENABLEWEIGHINGMODES
Samestepsarefollowedtoenableordisabletheweighingmodes.
1) Press[Enter]when“MODES”isdisplayed.Thedisplaywillshowthefirstmode
i.e., Parts Counting (“PARTS”) together with its enabled state “OFF” or “On”.
The user can enable or disable the parts counting mode by using [Up] or
[Down].Pressing[Enter]willconfirmthesettingandwilladvancetothenext
weighingmode.Repeatforeachmodeinturn
2) Press[Mode]toadvancetosettingofthenextmenuorpress [Esc] toreturn
tonormalweighing
12.3 ENABLESERIALINTERFACEPARAMETERS
Theparametersaffectingtheserialsetuparesetinasimilarmannerto theother
parameters.
Press[Enter]when “SERIAL” isdisplayedtoenterthesub‐menu.
Theparametersthatcanbesetare:
ENABLE TheserialportcanbesettoOnorOFF
BAUDRATE SettheBaudRateto4800,9600,19200or38400
PARITY SettheParitytoNONE,EVENorODD
8databitsandonestopbitarealwaysused,(8n1,8E1,8o1).
STABLE Toprintwhenstable(On)orregardlessofstability(OFF)
CONTINUOUS SettheRS‐232tosenddatacontinuouslytoOnorOFF
PERIODIC Setthe RS‐232 tosend data periodically (set in seconds) to On or OFF. If
On is selected, the value can be changed between 1 and 999 seconds,
using[Up]and[Down]
FORMAT
Tosenddata asasinglelineofdata,usingthestandardformatorusinga
customerdesignedformat(FORM1orFORM2).
During continuous or periodic printing only the weight is printed. Forms
arenotavailable.
31 | Page © Adam Equipment Company 2008