Owner manual

12.0EPUResistanceChart
* Let pump cool down completely before checking resistance. EPU checked
within 10 hours of operation can increase coil resistance reading as much
as 20%.
NOTES:
1. Pumps with serial numbers LOWER than: 960113429
2. Pumps with serial numbers HIGHER than: 960113429
Pump Series Voltage Coil Resistance
(Ohms)
@ 20
o
C (68
o
F)*
PW4, PW5, PW6
P04, P05, P06 115 VAC 76 - 87
P14, P15 P16 230 VAC 307 - 353
P74, P75, P76
(see Note 1)
P02, P03 115 VAC 152 - 176
P12, P13 230 VAC 583 - 671
(see Note 2)
AA14, AA74, AA94 115 VAC 76- 87
AA15, AA75, AA95 230 VAC 291- 335
AA16, AA76, AA96
AA17, AA77, AA97
P02, P03
P12, P13
J54D, J55D, J56D 12 VDC 1.1 - 1.3
E70, E71, E72, E73, E74 115 VAC 22.8 - 26.2
230 VAC 91 - 105
B11, B12, B13, B14 115 VAC 43 - 49
B71, B72, B73, B74, 230 VAC 167 - 193
B91, B92, B93, B84
C10, C11, C12, C13, C14 115 VAC 22.8 - 26.2
C70, C71, C72, C73, C74 230 VAC 91 - 105
C90, C91, C92, C93, C94
C76, C77, C78 115 VAC 14.4 - 16.6
230 VAC 57.7 - 66.3