Owner manual

10
4.0 Installation
4.1 Pump Location and Installation
Locate pump in an area convenient to solution tank and electri-
cal supply.
The pump should be accessible for routine maintenance, and
should not be subjected to ambient temperatures above 122°F
(50°C). If the pump will be exposed to direct sunlight, LMI black,
UV resistant tubing should be installed.
4.2 Pump Mounting
The pump can be mounted in one of two ways:
A. FLOODED SUCTION (ideal installation); or
B. SUCTION LIFT - when suction lift is less than 5 feet (1.5
m) for solutions having a specic gravity of water. For denser
solutions, consult distributor.
Your LMI metering pump must be mounted so that the suction
and discharge valves are vertical. NEVER position pump
head and ttings horizontally.
Electrical Connections
To reduce the risk of electrical shock, install only on a circuit
protected by a ground-fault circuit-interrupter (GFCI). The me-
tering pump must be plugged into a grounded outlet with ratings
conforming to the data on the pump control panel. The pump must
be connected to a good ground. DO NOT USE ADAPTERS!
All wiring must conform to local electrical codes.
WARNING: Do not hook a US style pump plug into a non-US (UK, Aust,
NZ or Swiss) wired power system. The US style 240VAC power system has
two 110VAC hot legs and one neutral. The European style system has one
240VAC hot leg and a neutral. Hooking up a US pump to the European
wired system will cause pump failure.