User Manual
6
INTRODUCTION
2.0 Introduction
LMI is the world’s most versatile manufacturer of economical and efcient metering
pumps. This manual addresses the installation, maintenance and troubleshooting proce-
dures for manually and externally controlled pumps. LMI has a worldwide network of
stocking representatives and authorized repair centers to give you prompt and efcient
service.
Please review this manual carefully. Pay particular attention to warnings and precautions.
Always follow good safety procedures, including the use of proper clothing, eye and face
protection.
2.1 Specications
AD2XY
(where X is any number;
where Y is 1, or 8)
AD2XY
(where X is any number;
where Y is 2,3,4,5,6,7, or 9)
AD8XY, or AD9XY
(where X is any number;
where Y is any number)
Operating
Temperature
14 to 113°F
–10 to 45°C
14 to 113°F
–10 to 45°C
14 to 113°F
–10 to 45°C
Voltage 110 to 120 V 220 to 240 V 95 to 240 V
Frequency 50 to 60 Hz 50 to 60 Hz 50 to 60 Hz
Max. Current 2.0 A 1.0 A 1.4 A
Wattage 25 W 22 W 20 W
AD2 AD8 AD9
Battery N/A N/A
Panasonic BR1225 or
Renata CR1225 or
Energizer/Eveready
CR1220
Fuse
Bel Fuse 5HT1.25-R
Time-lag, 5mm x 20mm
Bel Fuse 5HT 2-R
Time-lag, 5mm x 20mm
Bel Fuse 5H 2-R
Time-lag, 5mm x 20mm
* The battery and fuse are internal, factory serviceable parts, and must be replaced by the factory or a qualied
distributor with parts of the same type and rating.