User Manual
Table Of Contents
- _
- Foreword
- Introduction
- Section One: Simplex 4010 NION Hardware
- 1.1: General Description
- 1.2: Hardware Description
- Figure 1-1: NION-NPB Layout
- 1.3: SMX Network Connection
- Figure 1-2: SIMPLEX 4010 NION TB5 Power Connection
- 1.4: SMX Network Transceivers
- Figure 1-3: FTXC-PCA and FTXC-PCB Network Transceivers
- Figure 1-3a: FTXC-PCA Transceiver Wiring
- Figure 1-4: S7FTXC-PCA Style 7 Transceiver
- Figure 1-5: Sample Style-7 Networks
- Figure 1-6: FOXC-PCA and DFXC-PCA Fiber Optic Network Transceivers
- Section Two: Simplex 4010 NION Installation and Configuration
- 2.1: Simplex 4010 NION Connection
- Figure 2-1: Simplex 4010 NION Architecture
- Figure 2-2: Simplex 4010 NION to Simplex 4010-9811 Serial Connections
- 2.2: Simplex 4010 NION Enclosure and Mounting
- Figure 2-4: NISCAB-1 Enclosure Mounting Hole Layout
- 2.3 Event Reporting and Acknowledgement
- Figure 2-5: Installing the NION in a NISCAB-1
- Section Three: Simplex 4010 NION Explorer
- 3.1 Simplex Explorer Overview
- 3.2 Simplex 4010 Explorer Operation
- 3.2.1 Registering and Opening the Simplex Explorer
- 3.2.2 The Simplex 4010 Explorer Main Form
- 3.2.3 Configuring the NION through Simplex 4010 Explorer
- Figure 3-2: NION-Simplex 4010 Configuration Menu
- Figure 3-1: Simplex 4010 Explorer
- Figure 3-4: Duplicate Device Labels
- Figure 3-3: Learn Panel Devices Session
- Figure 3-5: Data Capture Mode
- Figure 3-6: NION Configuration Options
18
Simplex 4010 NION Installation/Operation Manual Version 2 Document 51998 Rev. A1 03/26/03
2.3 Event Reporting and Acknowledgement
Event Reporting
The Simplex 4010 NION reports events to a UniNet™ 2000 workstation in the format LllDddd where ll is the loop
and ddd the device. The Simplex 4010 FACP has one loop capable of handling 250 devices. If, for example,
device 001 on loop 01 goes into alarm or trouble the UniNet™ 2000 workstation will display the device as
L01D001. Note that all event reporting of the Simplex 4010 NION is strictly ancillary.
Event Acknowledgement
All events of the Simplex 4010 must be acknowledged at the panel. Acknowledging an event from the UniNet™
2000 workstation will not acknowledge the event on the Simplex 4010 panel.
Mounting Studs w/StandoffsMounting Studs w/Standoffs
Mounting Studs w/StandoffsMounting Studs w/Standoffs
Mounting Studs w/Standoffs
Mounting Studs w/StandoffsMounting Studs w/Standoffs
Mounting Studs w/StandoffsMounting Studs w/Standoffs
Mounting Studs w/Standoffs
Figure 2-5: Installing the NION in a NISCAB-1
Mounting NION boards within
the enclosure
When installing single NION boards in
this enclosure, be sure to use the
inboard set of four mounting studs as
shown below.
NOTE: This enclosure must
contain power limited wiring only.
NOTE: Use only wire for power
limited systems. Power limited wire
runs use type FPLR, FPLP, FPL or
equivalent cabling per NEC 760.
Simplex 4010 NIONSimplex 4010 NION
Simplex 4010 NIONSimplex 4010 NION
Simplex 4010 NION
NISCAB-1NISCAB-1
NISCAB-1NISCAB-1
NISCAB-1
NOTE: The Simplex 4010 Panel reports all battery charger events as panel events.
NOTE: The Simplex 4010 panel supports custom labels for devices. These custom
labels are shown in the description field of the device at the workstation. However
the ampersand (&), star. (*), plus (+), pound (#), comma (,), apostrophe (‘), caret
(^), and at (@) characters, if used in the custom label, will not be displayed in the
device description field at the workstation.
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com










