Instruction Manual
DN-60703:A1 • 9/19/2011 — Page 3 of 4
HFS-T: Honeywell Fire Systems addressable fixed tempera-
ture heat detector. Includes base.
HFS-MM: Honeywell Fire Systems addressable Mini-Monitor
module for normally-open contact devices.
HFS-MR: Honeywell Fire Systems addressable relay module.
HFS-D: Honeywell Fire Systems addressable photoelectric
duct smoke detector. Includes detector.
NOTIFIER EQUIVALENT DEVICES
NOT-BG12LX: Addressable dual-action manual pull station.
NP-100: Addressable low-profile photoelectric smoke detector.
NP-100T: Addressable low-profile photoelectric smoke detec-
tor with thermal sensor.
NH-100: Fast-response, low-profile heat detector.
DNR: InnovairFlex low-flow non-relay duct-detector housing;
uses NP-100R (ordered separately).
NP-100R: Addressable remote test capable detector for use
with DNR duct smoke detector housing.
NMM-100P: Miniature version of FMM-1. Excludes LED and
Style D option. Connects with wire pigtails. May mount in
device backbox.
NC-100R: Addressable relay module containing two isolated
sets of Form-C contacts, which operate as a DPDT switch.
N100-ISO: This module isolates the SLC loop from short cir-
cuit conditions
COMPATIBLE ANNUNCIATORS
N-ANN-80(-W): Remote LCD annunciator mimics the informa-
tion displayed on the FACP LCD display. Recommended wire
type is un-shielded. (Basic model is red; order -W version for
white; see DN-7114.)
N-ANN-SB80KIT-R: Red surface mount backbox with angled
wedge.
N-ANN-SB80KIT-W: White surface mount backbox with
angled wedge.
MISCELLANEOUS
SB-I/O: Surface-mount backbox for the NOT-BG12LX, plastic.
BG12TR: Optional trim ring for semi-flush mounting the pull-
station.
BB-26: Battery backbox, holds up to two 25 AH batteries and
CHG-75.
NFS-LBB: Battery box, houses two 55 AH batteries.
CHG-75: Battery charger for lead-acid batteries with a rating
of 25 to 75 AH.
CHG-120: Remote battery charging system for lead-acid bat-
teries with a rating of 55 to 120 AH. Requires additional NFS-
LBB for mounting.
BAT Series: Batteries.
See DN-6933.
005220: City Box Transmitter Module.
007860: DACT Phone Cord (2 required).
IPDACT-2/2UD, IPDACT Internet Monitoring Module:
Connects to primary and secondary DACT telephone output
ports for internet communications over customer provided eth-
ernet internet connection. Requires compatible Teldat
VisorALARM Central Station Receiver. Can use DHCP or
static IP.
(See DN-60408 for more information.)
IPSPLT: Y-adaptor option allows connection of both panel
dialer outputs to one IPDACT-2/2UD cable input.
IPENC: External mounting enclosure consisting of mounting
bracket IPBRKT, and screws. When using the supplied phone
cables, enclosure must be mounted within 6” (15.24 cm) of the
FACP. Red.
Wiring Requirements
While shielded wire is not required, it is recommended that all
SLC wiring be twisted-pair to minimize the effects of electrical
interference. Refer to the panel manual for wiring details.