– AMPS-24(E)*: 0.13 A.
(Draws power from secondary power source only.)
NOTE: See AMPS-24(E) Manual 51907 for a complete current
draw calculation sheet and details of input and output values.
Battery charger range: 7 AH – 200 AH. Use separate cabinet
for batteries over 26 AH.
Float Rate: 27.6 V.
SHIPPING WEIGHT
• CPU2-3030D: 5.95 lb (2.70 kg).
• CPU2-3030ND: 2.90 lb (1.32 kg).
TEMPERATURE AND HUMIDITY RANGES
This system meets NFPA requirements for operation at 0 –
49°C/32 – 120°F and at a relative humidity 93% ± 2% RH
(noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the
useful life of the system's standby batteries and the electronic
components may be adversely affected by extreme tempera-
ture ranges and humidity. Therefore, it is recommended that
this system and its peripherals be installed in an environment
with a normal room temperature of 15 – 27°C/60 – 80°F.
AGENCY LISTINGS AND APPROVALS
These listings and approvals apply to the modules specified in
this document. In some cases, certain modules or applications
may not be listed by certain approval agencies, or listing may
be in process. Consult factory for latest listing status.
• UL Listed: S635.
• ULC Listed: S527-11.
• MEA: 232-06-E.
• Fire Dept. of New York: COA#6211.
• CSFM: 7165-0028:0224 (Commercial).
• FM Approved.
• FM6320 Approved. Class 6320 for Gas Detection.
• City of Chicago.
• City of Denver.
• Singapore Productivity and Standards Board (PSB).
• CCCF listed.
• Fire Services Department (Hong Kong).
Marine Applications: Marine approved systems must be con-
figured using components itemized in this document. (See
Main System Components, in “Product Line Information.) Spe-
cific connections and requirements for those components are
described in the installation document, PN 54756. When these
requirements are followed, systems are approved by the fol-
lowing agencies:
• US Coast Guard 161.002/55/0 (Standard 46 CFR and
161.002).
•
Lloyd's Register 11/600013 (ENV 3 category).
• American Bureau of Shipping (ABS) Type Approval.
NOTE: For information on marine applications, see DN-60688.
STANDARDS
The NFS2-3030 complies with the following UL Standards and
NFPA 72, International Building Code (IBC), and California
Building Code (CBC) Fire Alarm Systems requirements:
• UL 864 (Fire).
• UL 1076 (Burglary).
• UL 2572 (Mass Notification Systems). (NFS2-3030 version
20 or higher)
• ULC-S527-11 Standard for the Installation of Fire Alarm Sys-
tems.
• LOCAL (Automatic, Manual, Waterflow and Sprinkler
Supervisory).
• AUXILIARY (Automatic, Manual and Waterflow) (requires
TM-4).
• REMOTE STATION (Automatic, Manual, Waterflow and
Sprinkler Supervisory) (requires TM-4).
• PROPRIETARY (Automatic, Manual, Waterflow and Sprin-
kler Supervisory). Not applicable for FM.
• EMERGENCY VOICE/ALARM.
• OT, PSDN (Other Technologies, Packet-switched Data Net-
work).
• IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis-
mic).
• CBC 2007 (Seismic).