Owner's Manual

Page 6 of 8 — DN-7070:P • 3/8/17
FSA-20000: Intelligent FAAST
®
XT Fire Alarm Aspiration
Sensing Technology. Intelligent aspirating smoke detector for
applications up to 28,800 sq.ft. For Canadian applications,
order FSA-20000A. See DN-60849.
FSA-20000P FAAST
®
XT PRO Intelligent Aspiration Detector For
applications up to 28,800 sq. ft. (2601 sq. m.) through one to four
addressable pipes. See DN-60792
FSB-200(A): Intelligent beam smoke detector. See DN-6985.
FSB-200S(A): Intelligent beam smoke detector with integral
sensitivity test. See DN-6985.
FSC-851(A): FlashScan IntelliQuad Advanced Multi-Criteria
Detector. See DN-60412.
FCO-851(A): FlashScan IntelliQuad PLUS Advanced Multi-Cri-
teria Fire/CO Detector. See DN-60689.
FSI-851(A): Low-profile FlashScan ionization detector. See
DN-6985.
FSP-851(A): Low-profile FlashScan photoelectric detector. See
DN-6935.
FSP-851R(A): Low-profile intelligent photoelectric sensor,
remote test capable. For use with DNR(W). See DN-6935.
FSP-851T(A): Low-profile FlashScan photoelectric detector
with 135°F (57°C) thermal. See DN-6935.
FST-851(A):: FlashScan thermal detector 135°F (57°C). See
DN-6936.
FST-851R(A): FlashScan thermal detector 135°F (57°C) with
rate-of-rise. See DN-6936.
FST-851H(A): FlashScan 190°F (88°C) high-temperature ther-
mal detector. See DN-6936.
FAPT-851(A): FlashScan Acclimate Plus™ low-profile multi-
sensor detector. See DN-6937.
FSL-751(A): FlashScan VIEW
®
laser photo detector. See DN-
6886.
DNR
(A): InnovairFlex low-flow non-relay duct-detector housing
(order FSP-851 separately). Replaces FSD-751PL/FSD-
751RPL. See DN-60429.
DNRW
(A): Same as above with NEMA-4 rating, watertight.
See DN-60429.
B224RB: Low-profile relay base. See DN-60054.
B224BI: Isolator base for low-profile detectors. See DN-
60054.
B210LP: Low-profile base. Standard U.S. style. Replaces
B710LP. See DN-60054.
B501
(A): European-style, 4" (10.16 cm) base. See DN-60054.
B200S: Intelligent programmable sounder base, capable of
producing a variety of tone patterns including ANSI Temporal
3. Compatible with sychronization protocol. See DN-60054.
B200S-LF: Low-frequency version of B200S. See DN-60054.
B200SCOA: Based on B200SA, with added CO detector
markings in English/French. For Canadian applications only.
B200SR: Sounder base, Temporal 3 or Continuous tone. See
DN-60054.
B200SR-LF: Low-frequency version of B200SR. See DN-
60054.
FMM-1(A):: FlashScan monitor module. See DN-6720.
FDM-1(A): FlashScan dual monitor module. See DN-6720.
FZM-1(A): FlashScan two-wire detector monitor module. See
DN-6720.
FMM-101(A): FlashScan miniature monitor module. See DN-
6720.
FMM-4-20: FlashScan 4-20 mA protocol monitor module. See
DN-60411.
FCM-1(A): FlashScan control module. See DN-6724.
FCM-1-REL(A): FlashScan releasing control module. See DN-
60390.
FTM-1(A): Firephone Telephone Module connects a remote
firefighter telephone to a centralized telephone console.
Reports status to panel. Wiring to jacks and handsets is super-
vised. See DN-6989.
FRM-1(A): FlashScan relay module. See DN-6724.
FDRM-1(A): FlashScan dual monitor/dual relay module. See
DN-60709.
NBG-12LX: Manual pull station, addressable. See DN-6726.
ISO-X: Isolator module. See DN-2243.
ISO-6: Six Fault isolator module. For Canadian applications
order ISO-6A. See DN-60844.
XP6-C
(A): FlashScan six-circuit supervised control module.
See DN-6924.
XP6-MA
(A): FlashScan six-zone interface module; connects
intelligent alarm system to two-wire conventional detection
zone. See DN-6925.
XP6-R
(A): FlashScan six-relay (Form-C) control module. See
DN-6926.
XP10-M
(A): FlashScan ten-input monitor module. See DN-
6923.
SLC-IM: SLC integration module, for VESDAnet detectors.
See DN-60755.
ENCLOSURES, CHASSIS, AND DRESS PLATES
CAB-4 Series Enclosure: NFS2-3030 mounts in a standard
CAB-4 Series enclosure (available in four sizes, “A” through
“D”). Backbox and door ordered separately; requires BP2-4
battery plate. A trim ring option is available for semi-flush
mounting. See DN-6857.
EQ Series Cabinets: EQ series cabinets will house amplifiers,
power supplies, battery chargers and control modules. EQ
cabinets are available in three sizes, “B” through “D”. See DN-
60229.
CAB-BM Marine System: Protects equipment in shipboard
and waterfront applications. Order CPU2-3030D-M; for non-
English marine applications order CPU2-3030D and appropri-
ate KP-KIT-XX. Also order BB-MB for systems using 100 AH
batteries. For a full list of required and optional equipment, see
DN-60688.
CHS-M3: Mounting chassis for CPU2-3030. One required for
each CPU2-3030D/3030ND.
CA-2: Chassis for FACP control panel when
DVC-EM is used
with firefighter's telephone. Mounts in the top two rows of a
CAB-4 series enclosure.
DP-DISP: Dress panel for top row in cabinet with CPU2-
3030D installed.
DP-1B: Blank dress panel. Provides dead-front panel for
unused tiers; covers DAA2/DAX series or AA-series amplifier.
See DN-7046.
CHS-BH1: Battery chassis; holds two 12.0 AH batteries.
Mounts on the left side of DAA2 chassis. See DN-7046.
CA-1: Chassis, occupies one tier of a CAB-4 Series enclosure.
The left side accommodates one
DVC-EM and a DVC-KD
(optional); and the right side houses a CMIC-1 microphone
and its well (optional). See DN-7045.
CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series
enclosure. The left side accommodates one
DVC-EM mounted
firealarmresources.com