Instruction Manual

Page 8 of 9 — DN-6856:A • 12/01/06
FZM-1: FlashScan® two-wire detector monitor module. See
DN-6720.
FMM-101: FlashScan® miniature monitor module. See DN-
6720.
FCM-1: FlashScan® NAC control module. See DN-6724.
FRM-1: FlashScan® relay module. See DN-6724.
FSM-101: FlashScan® pull station monitor module.
NBG-12LX: Manual fire alarm station, addressable.
See DN-
6726.
ISO-X: Isolator module. See DN-2243.
XP Series: Transponder. See DN-0759.
XP5-M: FlashScan® transponder, five monitor points. See DN-
6625.
XP5-C: FlashScan® transponder, five control points or Form-C
relays.
See DN-6625.
XP6-C: FlashScan® six-circuit supervised control module. See
DN-6924.
XP6-MA: FlashScan® six-zone interface module; connects
intelligent alarm system to two-wire conventional detection
zone.
See DN-6925.
XP6-R: FlashScan® six-relay (Form-C) control module. See
DN-6926.
XP10-M: FlashScan® ten-input monitor module. See DN-6923.
XPIQ: Intelligent quad transponder. See DN-6823.
OTHER OPTIONS
DPI-232: Direct Panel Interface, specialized modem for extend-
ing serial data links to remotely located FACPs and/or peripher-
als.
See DN-6870.
LEM-320: Loop Expander Module. Expands each 640 to two
Signaling Line Circuits.
See DN-6881.
TM-4: Transmitter Module. Includes three reverse-polarity cir-
cuits and one municipal box circuit. Mounts in panel module
position (single-address-style) or in CHS-M2 position.
See DN-
6860.
NCM-W: Network Communications Module, Wire. Order one
NCM per network node (CPU-640 or NCA).
See DN-6861.
NCM-F: Network Communications Module, Fiber. Order one
NCM per network node (CPU-640 or NCA).
See DN-6861.
NCS5-W-ONYX: Network Control Station, Wire. UL-Listed
graphics PC with mouse, 17" color flat-screen LCD monitor.
Order as necessary for network systems. Each NCS consumes
one of 103 network addresses. See DN-6868 (previous NCS-
W), ONYX® DN-6869.
NCS5-F-ONYX: Network Control Station, Fiber. UL-Listed
graphics PC with mouse, 17" color flat-screen LCD monitor.
Order as necessary for network systems. Each NCS consumes
one of 103 network addresses.
See DN-6868 (previous NCS-F),
ONYX® DN-6869.
VeriFire-TCD: VeriFire® Tools CD-ROM. Contains program-
ming software for the NFS-640, NCA, and XPIQ. Includes local
panel connection cable. Programming PC requires a serial port
connection. See DN-6871.
ACM-24AT: ONYX® Series ACS annunciator – up to 96 points
of annunciation with Alarm or Active LED, Trouble LED, and
switch per circuit. Active/Alarm LEDs can be programmed (by
powered-up switch selection) by point to be red, green, or yel-
low; the Trouble LED is always yellow.
See DN-6862.
AEM-24AT: Same LED and switch capabilities as ACM-24AT,
expands the ACM-24AT to 48, 72, or 96 points.
See DN-6862.
ACM-48A: ONYX® Series ACS annunciator – up to 96 points
of annunciation with Alarm or Active LED per circuit. Active/
Alarm LEDs can be programmed (by powered-up switch selec-
tion) in groups of 24 to be red, green, or yellow. Expandable to
96 points with one AEM-48A.
See DN-6862.
AEM-48A: Same LED capabilities as ACM-48A, expands the
ACM-48A to 96 points.
See DN-6862.
BAT Series: Batteries. NFS-640 utilizes two 12 volt, 12 to 55
AH batteries.
See DN-6933.
PS Series: Batteries. NFS-640 utilizes two 12 volt, 12 to 55 AH
batteries.
See DN-1109.
NFS-LBB: Battery Box (required for batteries over 25 AH).
BR: Same as above but red.