Instruction Manual
DN-6856:A • 12/01/06 — Page 7 of 9
AFM: Annunciator Fixed Modules AFM-16A, AFM-16AT, and
AFM-32A.
See AFM data sheet, DN-0056.
LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32.
See LDM data sheet, DN-0551.
ACM-8R: Remote Relay Module with eight Form-C contacts.
Can be located up to 6,000 ft. (1828.8 m) from panel on four
wires.
See ACM-8R data sheet, DN-3558.
SCS: Smoke control station; eight (expandable to 16) circuits.
See SCS data sheet, DN-4818.
RPT-485: Repeats EIA-485 over twisted pair or converts to
fiber-optic medium.
See RPT data sheet, DN-4737.
XP5: The XP5-M and XP5-C provide FlashScan® transponder
points.
See XP5 data sheet, DN-6625.
XP: The XP Series Transponder provides conventional monitor
and control points (CLIP mode only).
See XP Series data sheet,
DN-0759.
XPIQ: The XPIQ quad intelligent voice transponder for distrib-
uted multichannel voice evacuation systems, an integrated
audio amplification and distribution subsystem controlled by
FACP. Capable of playing up to four simultaneous messages.
Accepts up to four 25-watt amplifiers.
See XPIQ data sheet, DN-
6823.
CHS-4: Chassis for mounting up to four APS-6Rs.
CHS-4L: Low-profile four-position Chassis. Mounts two AA-30
amplifiers or one AMG-E and one AA-30.
DP-1B: Blank Dress panel. Provides dead-front panel for
unused tiers or to cover AA-30, AA-120, or one AMG-E and one
AA-30.
CAB-4 Series: The CAB-4 Series cabinets are fabricated from
16-gauge steel with unique full-front LEXAN®, reverse-silk-
screened for durability. The cabinet assembly consists of two
basic parts: a Backbox (SBB-_4), and a Locking Door (DR-_4)
that may hinge right or left. Cabinets are available in four sizes,
“A” through “D”, with one to four tiers. A trim ring option is avail-
able for semi-flush mounting.
See CAB-4 Series data sheet, DN-
6857.
CAB-M Series: Marine cabinets required for Lloyd’s Register
or U.S. Coast Guard listed use.
See DN-5063.
COMPATIBLE DEVICES, EIA-232 PORTS
PRN-5: 80-column printer. See DN-6769.
PRN-6: 80-column printer. See DN-6956.
VS4095/S2: Printer, 40-column, 24 V. Mounted in external
backbox.
Order from Keltron, Inc. See DN-3260.
CRT-2: Video display terminal. See DN-3756.
COMPATIBLE DEVICES, EIA-485 PORTS
ACS Series: Remote serial annunciator/control systems. See
DN-0524.
FDU-80: Remote LCD display, 80 characters, with LEDs. See
DN-6820.
LCD-80: Remote LCD display, 80 characters. See DN-3198.
LCD-80TM: Remote LCD display, 80 characters, terminal
mode.
See DN-3198.
LDM Series: Remote custom graphic driver modules. See DN-
0551.
ACM-8R: Remote relay module. 8 Form-C relays. See DN-
3558.
RPT-485 Series: Repeater, isolator and/or fiber-optic modem.
See DN-4737.
UDACT: Universal Digital Alarm Communicator Transmitter,
636 channel.
See DN-4867.
UZC-256: Zone Coder. Up to 256 programmable codes. See
DN-3404.
COMPATIBLE INTELLIGENT DEVICES
BEAMHK: Heating kit for transmitter/receiver unit of FSB-
200(S) below.
See DN-6985.
BEAMHRK: Heating kit for use with the reflector of FSB-200(S)
below.
See DN-6985.
BEAMLRK: Long-range accessory kit, FSB-200(S) below.
BEAMMRK: Multi-mount kit, FSB-200(S) below.
BEAMSMK: Surface-mount kit, FSB-200(S) below.
FSB-200: Intelligent beam smoke detector.
See DN-6985.
FSB-200S: Intelligent beam smoke detector with integral sensi-
tivity test.
See DN-6895.
FSI-851: Low-profile FlashScan® ionization detector, will
replace FSI-751.
See DN-6934.
FSI-751: Low-profile FlashScan® ionization detector. See DN-
6714.
FSP-851: Low-profile FlashScan® photoelectric detector, will
replace FSP-751.
See DN-6935.
FSP-751: Low-profile FlashScan® photoelectric detector. See
DN-6714.
FSP-851T: Low-profile FlashScan® photoelectric detector with
135°F (57°C) thermal, will replace FSP-751T.
See DN-6935.
FSP-751T: Low-profile FlashScan® photoelectric detector with
135°F (57°C) thermal.
See DN-6714.
FST-851: FlashScan® thermal detector 135°F (57°C), will
replace FST-751.
See DN-6936.
FST-751: FlashScan® thermal detector 135°F (57°C). See DN-
6716.
FST-851R: FlashScan® thermal detector 135°F (57°C) with
rate-of-rise, will replace FST-751R.
See DN-6936.
FST-751R: FlashScan® thermal detector 135°F (57°C) with
rate-of-rise.
See DN-6716.
FST-851H: FlashScan® 190°F (88°C) high-temperature ther-
mal detector.
See DN-6936.
FSD-751P: FlashScan® photo duct detector with housing. See
DN-6821.
FSD-751PL: Low-flow FlashScan® photo duct detector with
housing, will replace FSD-751P.
See DN-6955.
FSD-751RP: FlashScan® photo duct detector with relay and
housing.
FSD-751RPL: Low-flow FlashScan® photo duct detector with
relay and housing, will replace FSD-751RP.
See DN-6955.
FAPT-851: FlashScan® Acclimate Plus™ low-profile multi-sen-
sor detector, will replace FAPT-751.
See DN-6937.
FAPT-751: Acclimate Plus™ low-profile multisensor detector.
See DN-6833.
FSH-751: FlashScan® HARSH™ Hostile Area Smoke Head.
See DN-6875.
FSL-751: FlashScan® VIEW® laser photo detector, will replace
LPX-751.
See DN-6886.
LPX-751: Low-profile VIEW® laser photo detector. See DN-
5306.
B224RB: Low-profile relay base.
B224BI: Isolator base
for low-profile detectors.
B710LP: Low-profile base. Standard U.S. style.
B501: European-style, 4" (10.16 cm) base.
B501BH: Sounder base, includes B501 base above. Constant
tone.
B501BHT: Sounder base, includes B501 base above. Temporal
three tone.
FMM-1: FlashScan® monitor module.
See DN-6720.
FDM-1: FlashScan® dual monitor module. See DN-6720.
firealarmresources.com