Instruction Manual
SNAPON
DECORATIVE
RING
SCREWS(NOT
SUPPLIED)
DETECTOR
BASE
BOX(NOT
SUPPLIED)
SHORTING
SPRING
A78-1175-01
Figure1.MountingBasetoBox
MOUNTING
Thedetectorbasemountsdirectlyto3-1/2inchand
4-inchoctagonboxesand4-inchsquareboxes,with
or without plaster rings.To mount the base, remove
thedecorativeringbyrotatingitineitherdirectionto
unhookthesnapsbeforeseparatingtheringfromthe
base.Usethescrewssuppliedwiththejunctionbox
toattachthebasetotheboxthroughtheappropriate
slotsinthebase.
See Figure 1. Position the decorative ring around
thebaseandrotateitineitherdirectionuntilthering
snapsintoplace.
INSTALLATIONGUIDELINES
Allowableloopresistanceisanimportantspecication
forcontrolpanelsaswellasforsmokedetectorsand
their bases. The alarm system cannot be expected
to operate correctly if system components have in-
compatible allowable loop resistances. Therefore,
beforebeginninginstallation,refertothecontrolpanel
manufacturer’sloopresistancespecicationtoensure
thatitislistedascompatiblewiththeNotierbaseand
smokedetectorbeinginstalled.
All wiring must be installed in compliance with the
NationalElectricalCodeandallapplicablelocalcodes
and any special requirements of the authority hav-
ingjurisdiction,using the proper wire size.Thecon-
ductors used to connect smoke detectors to control
panelsandaccessorydevicesshouldbecolor-coded
to reduce the likelihood of wiring errors. Improper
connections can prevent a system from responding
properlyintheeventofare.
N550-01-00 2 I56-646-02R N550-01-00 3 I56-646-02R
NOTE: IFA REMOTE ANNUNCIATOR
IS NOT USED, POLARITY OF
THESE TERMINALS MAY BE
REVERSED.
A78-1175-03
Figure3A.ActivatingTamper-resistanceFeature Figure3B.RemovingDetectorHeadfromBase
PLASTICLEVER
BREAKTABAT
DOTTEDLINEBY
TWISTINGTOWARD
CENTEROFBASE.
USESMALL-BLADED
SCREWDRIVERTO
PUSHPLASTICLEVER
INDIRECTIONOF
ARROW.
PLASTICLEVER
BREAKTABAT
DOTTEDLINEBY
TWISTINGTOWARD
CENTEROFBASE.
USESMALL-BLADED
SCREWDRIVERTO
PUSHPLASTICLEVER
INDIRECTIONOF
ARROW.
2
3
4
1
REMOTE
ANNUNCIATOR
2
3
4
1
REMOTE
ANNUNCIATOR
2-WIRECONTROLPANEL
E
O
L
CLASSAOPTIONALWIRING
Figure2.WiringDiagramforaTypical2-WireDetectorSystem.
this.Afterthedetectorbaseiswiredandattachedtotheelectricalbox,positiontheshortingspringagainstterminal3.
Usetheslotintheretainingcliptoholdthespringagainsttheterminal,asshowninFigure1.Thisshortsthenegative-in
andnegative-outleadssothatloopwiringcanbetestedforcontinuity.
Theshortingspringinthebasewilldisengageautomaticallywhenthedetectorheadisremovedfromthebase.DONOT
removetheshortingspringsinceitreengagesasthedetectorheadisturnedintothebase,completingthecircuit.
TAMPER-RESISTANCEFEATURE
NOTE:DONOTusethetamper-resistancefeatureiftheXR2RemovalToolwillbeusedtoremovedetectorsfromthe
base.
Thisdetectorbasecanbemadetamperresistantsothatthedetectorcannotbedetachedwithouttheuseofatool.To
makethebasetamper-resistant,breakoffthesmallertabatthescribedlineonthetamperresistanttablocatedonthe
detectormountingbracket(seeFigure3A),beforeinstallingthedetector.
Toremovethedetectorfromthebaseafterithasbeenmadetamperresistant,removethedecorativeringbyrotatingitin
eitherdirectionandpullingitawayfromthebase.Then,insertasmallscrewdriverintothenotch,asindicatedinFigure
3B,andpresstheplasticlevertowardthemountingsurfacebeforerotatingthedetectorcounterclockwiseforremoval.
A78-1175-04
Forsignalwiring(thewiringbetweeninterconnecteddetectors),itisrecommendedthatthewirebenosmallerthanAWG
18.However,thescrewsandclampingplateinthebasecanaccommodatewiresizesuptoAWG12.Theuseoftwisted
pairwiringforthepower(+and-)loopisrecommendedtominimizetheeffectsofelectricalinterference.
NOTE:Toensurethatelectricalconnectionsaresupervised,doNOTloopwiresunderterminals2,3,and5-breakthe
wireateachterminal.
Tomakeelectricalconnections,stripapproximately3/8"(1cm)insulationfromtheendofeachwire.Slidethewiresunder
theclampplateandtightentheterminalscrew.
Checkthezonewiringbeforeinstallingthesmokedetectorhead.Thebuilt-inshortingspringmakesitconvenienttodo
www.PDF-Zoo.com