SDS
XII. ECOLOGICAL INFORMATION (continued)
CERIODAPHNIA DUBIA Nominal, static - 48 h LC50 = 1,830 mg/l
NITZSCHIA LINEARIS (DIATOM) Nominal, static - 5 day LC50 = 3,130 mg/l
XIII. DISPOSAL CONSIDERATIONS
WASTE DISPOSAL The generation of waste should be avoided or minimized wherever possible. This material and its container must be disposed of in a safe way.
Spilled material that has been swept up and dissolved in water should be used immediately in the normal application for which this product is
being consumed. If this is not possible, material may be neutralized. Please contact Norweco, Inc. for guidance. Note: Only properly neutralized
material should be ushed to sewer. Unneutralized material can cause environmental damage to receiving water or can interfere with treatment
plant operation. Care must be taken when using or disposing of chemical materials and/or their containers to prevent environmental contamination.
Empty containers retain product residue and can be hazardous. Residual material remaining in empty container can react to cause re. Thoroughly
ush empty container with water then destroy by placing in trash collection. Disposal of this product, solutions and any by-products should at all
times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Avoid
dispersal of spilled material, runo and contact with soil, waterways, drains and sewers.
DISPOSAL SHOULD BE IN ACCORDANCE WITH APPLICABLE NATIONAL, REGIONAL, STATE AND LOCAL LAWS AND REGULATIONS.
REFER TO SECTION VII: HANDLING AND STORAGE , SECTION VIII: EXPOSURE CONTROLS/PERSONAL PROTECTION FOR ADDITIONAL HANDLING INFORMATION AND PROTECTION OF
EMPLOYEES AND SECTION VI: ACCIDENTAL RELEASE MEASURES.
XIV. TRANSPORTATION INFORMATION
IDENTIFICATION NUMBER UN 2880
PACKING GROUP I I
REPORTABLE QUANTITY 10 pound/4.5 Kg
HMIS/NFPA RATING 3/0/1
I.M.O. DESCRIPTION Calcium Hypochlorite
Hydrated, Class 5.1, UN 2880
Packing Group I I, RQ 10, IMDG
Code Page 5138
U.S. DOT SHIPPING NAME Calcium Hypochlorite, Hydrated
U.S. DOT HAZARD CLASS 5.1 Oxidizer
XV. REGULATORY INFORMATION
UNITED STATES INVENTORY (TSCA 8b) All components are listed or exempted
AUSTRALIA INVENTORY (AICS) All components are listed or exempted
CANADA INVENTORY (DSL) All components are listed or exempted
CHINA INVENTORY (IECSC) All components are listed or exempted
EUROPE INVENTORY (REACH) Please contact your supplier for information on the inventory status of this material
JAPAN INVENTORY (ENCS) All components are listed or exempted
KOREA INVENTORY (KECI) All components are listed or exempted
NEW ZEALAND (NZLoC) All components are listed or exempted
PHILIPPINES INVENTORY (PICCS) All components are listed or exempted
UNITED STATES
EPA ID NO. - PESTICIDE Please contact your supplier to get the information
SARA 302/304 No products were found
CERCLA Hazardous substances:
pentasodium triphosphate 5000 lbs (2270 kg)
calcium hypochlorite 10 lbs (4.54 kg)
CHEMICAL NAME CAS# ACUTE CHRONIC FIRE REACTIVE PRESSURE
CALCIUM HYPOCHLORITE 7778-54-3 Y N N Y N
SODIUM CHLORIDE 7647-14-5 N N N N N
CALCIUM DIHYDROXIDE 1305-62-0 Y N N N N
CALCIUM CARBONATE 471-34-1 N N N N N
CALCIUM CHLORATE 10137-74-3 Y N N Y N
PRODUCT AS SUPPLIED Y N N Y N
CALIFORNIA PROP.
NOT APPLICABLE
CANADA
WHMIS (CANADA) Class E Corrosive solid
MEXICO
CLASSIFICATION
FLAMMABILITY 0 HEALTH 3 REACTIVITY 2
XVI. OTHER INFORMATION
OTHER SPECIAL NSF Standard 60 Drinking Water Treatment Chemicals - Some calcium hypochlorite brands have Health Eect Listing and are certied for
maximum use of 14-15 mg/l.
This product is registered with USEPA as a pesticide in all 50 states.
DATE OF ISSUE January 21, 2018
THIS SAFETY DATA SHEET IS OFFERED SOLELY FOR YOUR INFORMATION, CONSIDERATION AND INVESTIGATION. THE INFORMATION CONTAINED IN THIS DATA SHEET IS BASED ON PRESENT
SCIENTIFIC AND TECHNICAL KNOWLEDGE. THE PURPOSE OF THIS INFORMATION IS TO DRAW ATTENTION TO THE HEALTH AND SAFETY ASPECTS CONCERNING THE PRODUCT AND TO
RECOMMEND PRECAUTIONARY MEASURES FOR THE STORAGE AND HANDLING OF THE PRODUCT. NORWALK WASTEWATER EQUIPMENT COMPANY PROVIDES NO REPRESENTATIONS
OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, AND ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF THE DATA CONTAINED HEREIN. NO LIABILITY CAN
BE ACCEPTED FOR ANY FAILURE TO OBSERVE THE PRECAUTIONARY MEASURES DESCRIBED IN THIS DATA SHEET OR FOR ANY MISUSE OF THIS PRODUCT.
SAFETY DATA SHEET
BIO-SANITIZER
®
DISINFECTING TABLETS
DATE PREPARED: JANUARY 2018
PAGE 4