Product Manual
Page 18 of 22
Periodically tighten all bolts, nuts, and screws and check that all cotter pins are properly installed
to ensure the unit is in safe condition.
When completing a maintenance or service function, make sure all safety shields and devices are
installed before placing the unit in service.
After servicing, be sure all tools, parts, and service equipment are removed from the digger.
Do not allow debris, grease, or oil, to build up on the digger.
When replacement parts are necessary for periodic maintenance and servicing, genuine factory
replacement parts must be used to restore your equipment to original specifications.
The manufacturer will not be responsible for injuries or damages caused by the use of
unapproved parts and/or accessories.
A fire extinguisher and a first aid kit should be kept readily accessible while performing
maintenance on this equipment.
Troubleshooting
Always perform maintenance operations with the tractor engine off, the PTO drive disengaged, and
the auger point resting on the ground.
1. To remove the auger from the gear box output shaft, take out the two (2) 1/2” x 3-1/2” hex cap
screws.
2. To remove the drive shaft from the gear box input shaft, take out the shear pin bolt and the
1/4” set screw.
3. Check the oil level after every fifty hours of use. Use 80W- 90 lubricant and fill to the oil level
plug. All replacement lubricants should be of this type.
4. The universal joints should be greased with a good grade chassis lube every week. At the
beginning of each season, grease the sliding drive shaft members with moly grease.