Product Manual

46
Operation Using the Sprayer
C. Ensure uniform coverage
To ensure proper coverage, the height of the unfolded boom nozzles should be
about 20" from the ground. The sprayer must be level with the ground to get this
height.
Sprayer pattern as shown above for 5 sprayers
D. Begin to spray
Turn the remote switch ON to begin spraying.
9. Leaving
unattended
If the sprayer must be left unattended at any time:
a) Disconnect power to the sprayer.
b) Relieve system pressure by depressing the gun trigger.
c) Turn off the vehicle. Set brake or block the wheels.
10. Discontinue
use if clogged or
inoperative
If the sprayer becomes clogged or inoperative during use, discontinue use
immediately.
- DO NOT attempt to service while chemicals are in the sprayer and power is
connected.
- Return to service area to review instructions for troubleshooting before attempting
to service.
Note: A reserve, clean container capable of holding at least 41 gallons should be kept for use when the sprayer tank
needs to be emptied temporarily for repairs. It is advisable to purchase a reserve tank suitable for pesticide
storage from Northern Tool + Equipment for use in these circumstances. The container should be properly
labeled as to its contents if it is used.
20”
20”
20”
20”
20”
20”