Product Manual
Operation - Using the Sprayer (continued)
32
7. Check drain
cap and
battery
charge
Before filling tank, ensure drain cap is securely tightened. Also check that the
battery is fully charged by pressing the ON button on the battery monitor.
8. Fill tank
Add chemical to tank through fill cap:
a) Wear personal protective equipment while mixing. Goggles, gloves, long
sleeves, and pants are recommended. NOTE: Clothes may be damaged by
bleach.
b) Add to tank in this order:
1. Household bleach (6% sodium hypochlorite concentration)
2. NorthStar Max Cling Soft Wash Surfactant (NTE #81297 or #81298)
3. Water
c) Recommended mix ratios
Soft Wash
Mix
Surface to be Cleaned
Household
Bleach
NorthStar
Max Cling
Water
1%
Siding, screen enclosures
2 gallons
8 ounces
10 gallons
2%
Fences, decking
4 gallons
8 ounces
8 gallons
3%
Roofs, brick, stone, stucco,
concrete, driveways
6 gallons
8 ounces
6 gallons
NOTICE: Never spray undiluted bleach. It must be mixed with water and NorthStar
Max Cling Soft Wash Surfactant. Failure to do so could result in unforeseen damage
to vegetation or the cleaning surface. Always test soft wash mix in an inconspicuous
area to confirm compatibility.
NOTICE: Not for use on painted wood surfaces. Use only on hard, non-porous
surfaces.
WARNING: Never exceed 3%, higher concentrations will increase the risk of damage
to the sprayer. For difficult stains, repeat applications may be required.
9. Replace fill
cap
Replace fill cap and tighten securely.
Drain cap
Battery monitor